Fig.32:
Loosening the clamp screw
!
Make sure that the clamp can be moved by hand and without a great
deal of force before you carry out the next step. If this is not the case, use
a plastic hammer to knock the clamp segments carefully until the pressure
escapes and the clamp can then be moved without any problem.
3.
Carefully take off the clamp from the valve.
4.
Carefully lift the actuator with the internal assembly out of the housing.
! Do not damage the sealing surface on the valve housing.
Fig.33:
Removing actuator and internal assembly
®
Internal assembly and actuator are now separated from the housing.
Maintenance
Disassembling and Assembling the Valve
430BAL011547EN_2
08.07.2019
39