– 10 –
Pull up
2 Air filters
Up-Front Air Filters
There are 2
interchangeable up-
front fi lters that are
easy to remove and
reinstall. These may
be cleaned without
opening or removing
the room cabinet.
Clean the fi lters by brushing, vacuuming or back-
fl ushing under a faucet or shower head.
Easy Clean Air Discharge Area
The 2800 and 3800 series units have an out-of-
sight vertical protective screen over the indoor fan.
This allows easy cleaning of air discharge area by
simply removing room front and wiping clean. There
is no screen directly below discharge louver to trap
unsightly dirt and debris where it may be seen by
room occupant.
Concealed Manual Vent Control
The 3-position manual
vent door control may
be closed, partially
open, or fully open.
Vent CFM High Speed
Unit Full
Open
Partial
Open
7000 50 40
9000 70 45
12000 75 45
15000 75 45
CFM ratings at 230 volts and 265-volts.
• Greater amounts of air will be introduced if the
room has an exhaust fan.
• An open vent door brings unconditioned outdoor
air into the room, increasing heating and cooling
costs.
• Positive vent door closure prevents accidental
opening and unwanted air infi ltration.
Corrosion Protection (Optional)
The 2800 and 3800 Series units may be ordered
with special protection to better withstand damage
from salt air and salt water in seacoast areas.
Corrosion Protection
Corrosion protection is standard on Dry Air 25
models and optional on non-Dry Air 25 models.
Heat pump units with ICR are not available with
corrosion protection and should not be installed in
seacoast or corrosive environments.
Units installed in corrosive areas should be
examined and cleaned more frequently than normal
installations.
Enhanced Dehumidifi cation
Moisture removal is an important function of an air
conditioner. People are more comfortable at higher
temperatures when the humidity level is relatively
low. Air conditioners operate with less energy
consumption when the room temperatures are set
higher.
The GE Zoneline 2800 series with the Dry Air 25 heat
pipe application removes 25% more moisture than
the base 2800 Series unit. This equates to up to 2.7
additional gallons of moisture removed per day.
The GE Zoneline Dry Air 25 chassis is the only PTAC
available with the application of the patented Dinh
Dehumidifi er Heat Pipe under license from Heat Pipe
Technology, Inc.
Customers who are using the Dry Air 25 report
a fresher-smelling room as a result of the lower
humidity levels, as well as lower operating costs.
Locking Door Kit
RAK8023 ― A door with a lock that replaces
the standard control cover door to prevent
unauthorized changing of control setting is offered
as an accessory.