32
RAB71/77 W
ALL CASE INST
ALLA
TION - RAK204 SERIES SUB-BASE CONNECTED
EXAMPLE: FRAME & BRICK VENEER - DIMENSIONAL DA
T
A
AND COMMENTS
ARE ALSO APPLICABLE TO OTHER TYPES OF CONSTRUCTION
TOP VIEW
Manufacturer Required
Minimum Installation Clearance
1/4" (See note 1)
3" Min. (5" MAX.)
2-3/8" Minimum
0" Minimum 2" Recommended
See pages 38-39 for ducted application.
Dimension
A
B
C
D
NOTE:
1. FOR OUTSIDE FLUSH MOUNTING SEE P
AGE 31 FOR
DRAIN INST
ALLA
TION.
2-3/8"
MIN.
FINISHED
INTERIOR
W
ALL
LEVELING SCREW
LEVELING SCREW
RAB71 13-3/4"
RAB77 13-7/8"
5.15"
7.70"
18.86"
1.5"
5.15"
7.70"
10.30"
8.80"
BACK VIEW
FRONT VIEW
42"
D
D
SEE NOTE
LEFT SIDE
INTERIOR
ADJACENT
W
ALL
12-3/4"
1
2-7/8"
13"
LEVELING SCREW
KNOCKOUT SIZE
LARGE 1-1/8" DIA.
SMALL 7/8" DIA.
KNOCKOUTS
(ENCLOSURE)
4 REAR; 4 BOTTOM
*SHOWN WITH ACCESS COVERS REMOVED.
NOTE: CAUTION - REMOVE KNOCKOUTS FROM INSIDE OUT
.
SIDE VIEW
WITH W
ALL
CASE SHOWN
IN PLACE
FINISHED FLOOR
3" MIN.
ADJUST
ABLE
TO 5"
1-5/16"
2-3/8"
INTERIOR
W
ALL
RAB71 16"
RAB77 16-1/4"
7/8"
1-1/2"
FINISHED FLOOR
RAB71 16"
RAB77 16-1/4"
SIDE VIEW
MAX. W
ALL THICKNESS
11-1/8"
MOUNTING SCREWS
AND HOLES BY
INST
ALLER
LEVELING SCREWS
(2) SUB-BASE BODY
(2) SIDE EXTENSIONS
CONDUIT ENTR
Y
(AL
TERNA
TES)
CAULK*
ROOM
CABINET
C
A
B
CAULK*
3-11/16"
2-3/8" MIN. CASE
EDGE TO FINISHED
W
ALL
13-3/4"
CAULK*
*Caulk around
perimeter of
wall case all
four sides
where it joins
the building -
Interior and
Exterior
.
RECOMMEND 2" TO
INTERIOR ADJACENT
W
ALL BOTH SIDES.
1719 Data Manual 2001 2/14/02 3:12 PM Page 32