8
Zoneline
®
Features
Model Series
AZ
AZ
AZ
2500
3500
5500
Enhanced Dehumidification - Dry Air 25
Optional
N/A
N/A
Cooling EER Range (230 Volts/265 Volts)
9.6 - 11.6
9.6 - 11.6
10.0 - 12.0
Heating COP Range (230 Volts/265 Volts)
N/A
3.1 - 3.5
3.1 - 3.5
Heat Source - Electric Resistance Heat
Page 54
—
—
Heat Source - Heat Pump With
—
Std. Pages
—
Backup Resistance Heat
19, 55
Heat Source - Heat Pump With Selectable
Full Time or On Demand Simultaneous/
—
—
Std. Pages
Supplemental Resistance Heat
20, 55
Staged Heating
—
2 Stage
3 Stage
Universal Heater
—
—
Standard
Automatic Emergency Heat
—
Standard
Standard
Highly Featured Microprocessor Controls
Standard
Standard
Standard-Plus
Electric Resistance Heat Lock-Out (above 46°F)
—
—
Standard
Heat Pump Defrost System
—
Passive
Reverse Cycle
Unit Diagnostics
—
—
Standard
Quick Heat Recovery
—
Standard
Standard
Service Indicator
—
—
Temp Display Blinks
Touch Controls (Tactile Controls)
—
—
Standard
Electronic Temperature Selection
—
—
Standard
(Slews Up & Down) with Digital Display
Rotary Control Knobs
Standard
Standard
—
Fan Motors - Permanently Lubricated
2
2
2
2 Speed Outdoor Fan
Standard
Standard
Standard
Indoor Fan Speed Selections - AUTO/HIGH
Standard
Standard
Standard
Fan Only Setting - HIGH/LOW
Standard
Standard
Standard
Fan Cycle Switch
“Smart Fan”
“Smart Fan”
“Smart Fan”
Rotary Compressor
Standard
Standard
Standard
Automatic Compressor Restart Delay
Standard
Standard
Standard
Power Connection Cord
Included
Included
UPC*
Freeze Sentinel
TM
Standard
Standard
Standard
Indoor Coil Frost Control
Standard
Standard
Standard
Transfer Fan Connections
Standard
Standard
Standard
7 Step Electronic Temperature Limiting
Standard
Standard
Standard
Energy Management System Interface
Standard
Standard
Standard
Remote Control Capability
Standard
Standard
Standard
With Wall Mounted Thermostat
Central Desk Control Capability
Standard
Standard
Standard
With Load Shedding Option
Reversible Indoor Air Louvers 40°/50°
Standard
Standard
Standard
Up-Front Filters
Standard
Standard
Standard
Easy Clean Air Discharge Area
Standard
Standard
—
Concealed Manual Vent Control
Standard
Standard
Standard
Ducted Installation Capability
RAK6052
RAK6052
—
Corrosion Treated
Optional
Optional
—
Internal Condensate Removal (ICR)
N/A
Optional
Optional
Factory Installed Option.
Cannot be used in Corrosion Areas.
*UPC - Universal Power Cord Connection (See pages 42, 43 and 55)
**265 volt units must be connected in a manner to meet National Electrical Code and all local codes.
1719 Data Manual 2001 2/14/02 3:11 PM Page 8