Installation Instructions

466-1873 Rev G
January 2003

Simon Security 
System

Part No:
60-875 
60-910 (Not investigated for use by UL)

ZZZ*(,QWHUORJL[FRP

Summary of Contents for Simon Security System

Page 1: ...stem Status Doors Windows Motion Sensors Arm Disarm 9 0 5 6 3 4 7 8 1 2 On Off Sensor Motion Time Doors Lights Chime AUX Test Weekly POLICE FIRE Installation Instructions 466 1873 Rev G January 2003 S...

Page 2: ...ephone network must comply with the applicable FCC Part 68 rules and require ments as adopted by ACTA A compliant telephone cord and modular plug is provided with this product It is designed to be con...

Page 3: ...t riel l utilisateur doit s assurer qu il est permis de le raccorder aux installations de l enterprise locale de t l communi cation Le mat riel doit galement etre install en suivant une m thod accept...

Page 4: ...Numbers 7 Installing the System 8 Materials Needed 8 Opening the Panel Cover and Chassis 8 Mounting the Panel 9 Connecting Hardwire Devices 10 AC Terminals 10 HWIN1 HWIN2 and DCOUT Terminals 10 Wiring...

Page 5: ...5 Option 21 Opening Reports 26 Option 22 Closing Reports 26 Option 23 Force Armed Report 26 Option 24 AC Power Failure Report 26 Option 25 CPU Low Battery Report 26 Option 26 Fail to Communicate 27 Op...

Page 6: ...Quick Exit 37 Option 68 Swinger Shutdown 37 Option 69 SIA Limits 37 Option 70 Not Available 38 Option 71 Programming Report 38 Option 72 Supervisory Time 38 Option 73 Modem Sensitivity 38 Option 74 Si...

Page 7: ...stem Status 49 Control Panel 50 Options Programmable by the homeowner 50 Sensors 50 X10 Modules 51 Appendix B System Configuration 52 Sensor Assignments Locations 52 Alphabetical Listing of Sensor Nam...

Page 8: ...75 11 3 with 2 way voice and transmitter Backup Battery 6V 1 2 AH 34 025 Standard Class II 9 VAC 700 mA Power Transformer 22 109 or Class II 9 VAC 700 mA Line Carrier Power Transformer 22 129 Hardwire...

Page 9: ...with the following central station receivers using SIA and Contact ID reporting formats Note Before beginning installa tion installers must verify compatibility with the follow ing central station rec...

Page 10: ...omponents The security system has three types of components the control panel devices that report to the panel and devices that respond to commands from the panel see Figure 1 Figure 1 Typical Securit...

Page 11: ...or up to 24 sensors and may use any of the following Door Window Sensor 60 670 For intrusion protection install Door Window sensors on all ground floor doors and windows At a minimum install them in t...

Page 12: ...a police or auxiliary panic alarm Random encrypted signal transmissions pro vide high security to help prevent signal copying Remote Handheld Touchpad 60 671 The Remote Handheld Touchpad lets you turn...

Page 13: ...s disarm arm doors windows arm motion sensors and arm doors windows and motions sensors Device Locations Control Panel Locate the panel where alarm sounds can be heard and is easily accessible for ope...

Page 14: ...remote siren can be set to any unit number to hear alarm sounds Set it to unit number 9 to also hear arming level beeps status beeps and trouble beeps Do not use a lamp module to control appliances Us...

Page 15: ...l Time activated lights are enabled and disabled by pressing the LIGHTS Time Activated button on the panel If using the universal module to operate a device be sure to assign a unique unit number The...

Page 16: ...or mounting hole locations For wall mounting hold the panel against the wall and mark the mounting hole locations with a pencil For Tabletop Base mounting place the panel back on the base until the to...

Page 17: ...not pro vide both functions simulta neously Sirens From the factory these terminals are set up for siren operation with HWIN1 handling interior sirens status and alarm sounds HWIN2 handling exterior s...

Page 18: ...be used for connecting exterior sirens and activates when intrusion and fire alarms occur Exterior sirens can be wired with or without a resistor in the circuit for supervision For circuit supervision...

Page 19: ...does not provide supervision of the wire The total resistance of the wire loop must not exceed 3 ohms This allows you to use up to 200 feet of 2 conductor 22 gauge stranded wire Connect hardwire reed...

Page 20: ...connectors for these splices 4 Connect the 4 conductor cable Green and Red wires to the TELCO block TIP and Red to RING posts D in Figure 8 Figure 8 Full Line Seizure Wiring with an RJ 31X Full Line S...

Page 21: ...Connect the power transformer to the panel AC terminals as shown in Figure 10 Note Do not plug in the trans former at this time Figure 10 Connecting the Power Transformer Powering Up the Panel When ap...

Page 22: ...nt from all other X10 modules between 1 and 8 2 Set the house code for the installation 3 Plug the module into a wall outlet 4 Plug the lamp appliance into the module Universal Module Note See Light a...

Page 23: ...l The system prompts you through programming steps with beeps and voice mes sages Program the panel in this order 1 Set the panel clock 2 Add learn sensors 3 Set House Code and Light Appliance Control...

Page 24: ...are separated The following table Device Programming describes the programming button loca tion for each device Device Programming Device To Program Door Window Sensor Press button on top of sensor c...

Page 25: ...nnouncing the sensor num ber name and group To delete sensors 1 Press Delete The panel announces Select from Main Menu 2 Press Sensor Remote repeatedly until you hear the name and number you want dele...

Page 26: ...ss DONE The panel confirms your programming To add a time activated module 1 Press Add 2 Press Light Control 3 Press Unit until you hear the unit number that matches the one you chose on the module 4...

Page 27: ...Piezo Beeps press Delete Option 01 DONE Panel Piezo Beeps Activity Piezo Beep Response ARM Doors Windows Exit Delay 2 beeps sound every 5 seconds and 2 times per second during the last 10 seconds Sile...

Page 28: ...number is automatically stored without pressing DONE if all 26 places are used To delete Primary Phone Number press Delete Option 04 DONE Option 05 Secondary Phone Number Default none Lets you progra...

Page 29: ...ory clear is performed on or resets these options to their default values when a memory clear is performed off To turn on Phone Lock press Add Option 08 DONE To turn off Phone Lock press Delete Option...

Page 30: ...Option 12 Phone Mod 1 Default 0 Determines the primary phone number Option 4 report content and reporting format Note UL has only verified report ing compatibility with the CS5000 Digital Alarm Com mu...

Page 31: ...t be 2 digits To set No Activity Time out press Add Option 15 02 24 DONE To turn off No Activity Time out press Delete Option 15 DONE Option 16 Auto Phone Test Default off Determines whether the panel...

Page 32: ...ed time the panel sends an alarm cancel message to the central station An alarm cancel message is not reported if the system is disarmed after the programmed time expires The time can be set from 005...

Page 33: ...urn off Force Armed Report press Delete Option 23 DONE Option 24 AC Power Failure Report Default off Determines whether the panel sends AC power failure reports to a central station or pager after the...

Page 34: ...rings The panel should answer after the tenth ring For off site access where an answering machine exists the user or ToolBox operator must perform the following steps 1 Call the panel location 2 Let...

Page 35: ...ONE To turn off Panel Panic Alarms press Delete Option 30 DONE Option 31 Downloader Enable Default on Determines whether the panel can be accessed using ToolBox on or not off To turn on Downloader Ena...

Page 36: ...e Option 37 Note Both Options 36 and 37 must have a time pro grammed for this feature to work correctly When both Options 36 and 37 are turned off and the sensor activated lights feature is on sensor...

Page 37: ...ned during the exit delay they will also be bypassed if left open To turn off Auto Arm press Delete Option 38 DONE Option 39 Siren Timeout Default 4 min Determines how long sirens sound alarms if no o...

Page 38: ...n the pager display to iden tify the report When used to call a remote phone a person at the remote phone location can hear system voice alarm announcements See the Testing section for more infor mati...

Page 39: ...om the central sta tion operator before starting an audio session on or stays on line with the central sta tion for an instant audio session off Note Option 33 Audio Verification must be on for this f...

Page 40: ...ensor tamper switch is tripped on or only when the system is armed and a tamper switch of an armed sensor is tripped off To turn on 24 Hour Tamper press Add Option 51 DONE To turn off 24 Hour Tamper p...

Page 41: ...system access codes Master Utility 1 Utility 2 Panic and User Changing the access code length changes the Master Utility 1 and Utility 2 access codes to their respective defaults as described in the...

Page 42: ...quired to report as a tamper To report supervisories as Tamper Reports press Add Option 57 DONE To report supervisories as Supervisory Reports press Delete Option 57 DONE Option 58 Remote Touchpad Arm...

Page 43: ...61 DONE Option 62 Supervisory Protest Default off Determines whether the panel protests arming if it has not received a supervisory sig nal from any sensor 15 minutes before arming on or not off Note...

Page 44: ...Exit Default off Determines whether pressing the Disarm button when the system is armed activates the exit delay time to allow exit and re entry without disarming the system on or not off This feature...

Page 45: ...anel reports supervisory conditions sensor failures and auto matic phone tests to the central station Note The panel clock must be set to the correct time for this option and Option 16 Auto Phone Test...

Page 46: ...est results this option should be set equal to or greater than Option 75 VOX Mic Gain For panels with a built in microphone this option should be set to the default value To set VOX Gain Range press A...

Page 47: ...he panel verifies successful alarm reports to the central station pager with the voice message Phone communication okay on or not off To turn on Alarm Report Verification press Add Option 80 DONE To t...

Page 48: ...e Panic Code is able to arm disarm or subdisarm the panel and send a silent alarm to the Central Station There will be no indication of an alarm at the panel To add a code 1 Press Add 2 Press Access C...

Page 49: ...If Option 41 Chime Voice is on the panel speaker also announces the sensor name and number LIGHTS Time Activated Press to enable system controlled lights to turn on off at a scheduled time LIGHTS Sen...

Page 50: ...r window Freeze Apply ice in a plastic bag to the sensor Do not allow the sensor to get wet Water Press a wet rag or wet finger over both of the round gold plated terminals on the underside of the sen...

Page 51: ...ensor if necessary replace the sensor To reposition a sensor 1 Rotate the sensor and test for improved sensor communication at 90 and 180 degrees from the original position 2 If poor communication per...

Page 52: ...e by UL Off Site Phone Operation Test the system from a remote phone by calling the panel and using the commands in the following table Central Station Communication After performing sensor and phone...

Page 53: ...angs up 1 After the panel has completed reporting the alarm pick up the CS phone and press the button to start the audio session 2 Press 1 or 0 to speak 2 for VOX operation and 3 or 6 to listen 3 Pres...

Page 54: ...s have been identified the panel announces Press to exit 6 Press to terminate the call RF Thermostat Operation The following information is important for the RF Thermostat to function through your con...

Page 55: ...eout expires Siren priority is as follows 1 Fire highest priority 2 Intrusion 3 Emergency Note The X10 Siren must be set to unit 9 to hear emer gency alarms and Status Beeps To hear emer gency alarms...

Page 56: ...located between the sleeping area and the rest of the family living unit NOTE Do not install smoke detectors where normal ambient temperatures are above 100 F or below 40 F Also do not locate detecto...

Page 57: ...3 is not set Set Latchkey time Latchkey is not enabled Enable Latchkey by pressing ARM Motion Sensors twice The phone number is not programmed properly Reprogram the phone number options 13 or 43 Syst...

Page 58: ...h on the lamp or appliance is turned on and remains on Make sure the lamp has a working bulb Make sure the lamp or appliance is plugged into the Lamp Appliance Module the Module is plugged into the ou...

Page 59: ...rage Door Garage Window Guest Room Guest Room Window Hallway Keychain Remote Kitchen Kitchen Window Laundry Room Laundry Room Window Living Room Living Room Window Mas ter Bedroom Master Bedroom Windo...

Page 60: ...layed Interior interior doors that initiate a delay before going into alarm Intrusion S Yes Yes 34 20 Delayed Interior PIR motion sensors that initiate a delay before going into alarm Intrusion S No Y...

Page 61: ...Name Application Siren Type Delay Restoral Supervisory Active in Levels This type is not certified as a primary protection circuit for UL listed systems and is for supplementary use only This type is...

Page 62: ...1 09 Downloader Code 12345 12345 00000 99999 U1 10 Entry Delay must be 45 seconds for UL listed systems 030 sec 005 sec 005 254 sec 030 254 if Option 69 is added U1 U2 11 Exit Delay must be 60 seconds...

Page 63: ...ight 11 59 PM U1 U2 M 38 Auto Arm must be added for UL listed systems Off Off On Off U1 U2 39 Siren Time Out must be greater than 4 minutes for UL listed systems 04 min Siren never times out 002 254 m...

Page 64: ...Swinger Shutdown On Off On Off U1 U2 69 SIA Limits On Off On Off U1 70 Not Available 71 Programming Report Off Off On Off U1 U2 72 Supervisory Time Midnight Off 12 00 Midnight 11 59 PM U1 U2 73 Modem...

Page 65: ...no AC and specified standby load Radio Frequency 319 5 MHz 60 875 433 MHz 60 910 Nominal Range 500 feet open air receiving range Storage Temperature Range 29 to140 F 34 to 60 C Operating Temperature R...

Page 66: ...Simon Security System 59...

Page 67: ...Simon Security System 60...

Page 68: ...Sensor Activated Lights On Off Turn On Special Lights Turn All Lights On Turn All Lights Off ARM Motion Sensors ARM Motion Sensors Enter Master Code while system is disarmed Press once Press once Pres...