20
49-5000517 Rev. 2
Troubleshooting tips
Problem
Solution
No Display
Check for 24 VAC at thermostat and-
batteries; display is blank when 24 VAC
is not present and batteries are bad.
System fan does not
come on properly
Verify that wiring is correct.
All thermostat buttoms
are inoperative
Verify that 24 VAC is present; unit
will not operate when 24 VAC is not
present.
Thermostat turns on
DQGRႇWRRIUHTXHQWO\
$GMXVWWHPSHUDWXUHGLႇHUHQWLDOVHH
&RQ¿JXUDWLRQ0RGH6HWWLQJ7HPSHUD
-
WXUH'LႇHUHQWLDO6WDJHDQG6WDJH
sections).
Program schedule
activates at the wrong
time
Check time (AM/PM) set on thermostat
(see Programming).
Thermostat does not
follow program
Verify that it is in Program mode;
PROG displays solid; check time (AM/
PM); check if in Hold mode (PROG
ÀDVKLQJ
352*ÀROG
mode)
Press Hold button to remove from Hold
mode
Fan runs continuously
Check Fan Auto/On switch. If set to ON
position, fan will run continuously.
Room temperature is
not correct
Verify that wall hole is plugged with
SXWW\RULQVXODWLRQWRSUHYHQWDLUÀRZ
from the wall cavity. Adjust Temperature
2ႇVHWVHH&RQ¿JXUDWLRQ0RGH5RRP
WHPSHUDWXUHRႇVHWVHFWLRQ
Compressor doesn’t
UXQRUWXUQRႇLPPH-
diately when changing
function or setting
There is a 3 minute time delay and
a 3 minute minimum run time for the
FRPSUHVVRUZKHQLWWXUQVRQRႇ