Configuration mode
The configuration mode is used to set the thermostat to match
the heating/cooling system. This thermostat will function with
up to 2-stage heatpump systems. To configure the thermostat,
perform the following steps:
NOTE:
Operation being set will blink in the display.
1.
Slide the
Function
switch to the
OFF
position.
2.
Simultaneously hold the
<
and
>
buttons in
for 6 seconds while the thermostat is in
OFF
mode.
3.
Press the
<
or
>
button to change settings within
each screen.
4.
Press the
Hold
button to advance to the next screen.
Note:
The
Mode
button will return you to the previous screen.
5.
To save the changes and exit configuration mode, slide the
Function
switch to
Heat
or
Cool
.
Configuration Mode Settings
The setup screens for Configuration Mode are as follows:
1.
Temperature Scale (F or C)—
Choose
Fahrenheit or Celsius.
Press the
<
or
>
button
to select.
Press the
Hold
button to advance to the next screen.
NOTE:
Default factory setting is Fahrenheit
.
2.
Heat System—
Check model number on the GE PTAC
chassis to determine the primary heating method.
AZ65H/95H*****
are heat pumps and is the thermostat factory
setting.
AZ45E/95E*****
are electric heat models and will require a
mode setting change.
To change the heating mode configuration, press the
<
or
>
button. Select
HPb
screen for heat pump or select
ELE
screen for electric heat.
Press the
Hold
button to advance to the next screen.