TROUBLESHOOTING TIPS
Problem
Solution
No Display
Check for 24 VAC; display is blank
when 24 VAC is not present
System fan does not
come on properly
Verify that wiring is correct.
All thermostat but-
tons are inoperative
Verify that 24 VAC is present; unit
will not operate when 24 VAC is not
present.
Thermostat turns on
DQGRႇWRRIUH-
quently
$GMXVWWHPSHUDWXUHGLႇHUHQWLDO
VHH&RQ¿JXUDWLRQ0RGH6HWWLQJ
7HPSHUDWXUH'LႇHUHQWLDO6WDJHDQG
Stage 2 section).
Fan runs continu-
ously
Check
Fan Auto/On
switch. If set to
ON
position, fan will run.
Room temperature
is not correct
Verify that wall hole is plugged with
SXWW\RULQVXODWLRQWRSUHYHQWDLUÀRZ
from the wall cavity. Adjust Tempera-
WXUH2ႇVHWVHH&RQ¿JXUDWLRQ0RGH
5RRPWHPSHUDWXUHRႇVHWVHFWLRQ
Compressor doesn’t
UXQRUWXUQRႇLP-
mediately when
changing function
or setting
There is a 3 minute time delay and
a 3 minute minimum run time for the
FRPSUHVVRUZKHQLWWXUQVRQRႇ
Fan doesn’t run or
WXUQRႇLPPHGL-
ately when changing
function or setting
This is normal. On some models, the
IDQPD\KDYHDPLQLPXPUXQWLPHRႇ
time delay.
Problem not listed
above
Press the
Reset
button once to reset
the thermostat and restore all factory
settings.