background image

INSTALLATION INSTRUCTIONS

69-1677EF-03

T8775A,C 

The Digital Round

 

NON-PROGRAMMABLE THERMOSTAT

The T8775A,C Thermostats provide single-stage 
temperature control for 24V systems. The 
T8775A,C models include a thermostat, wallplate 
(for wiring and mounting thermostat), mounting 
screws, wall anchors, and a 4074 FAB resistor.

MERCURY NOTICE

If this control is replacing a control that 
contains mercury in a sealed tube, do 
not place your old control in the trash.

Contact your local waste management 
authority for instructions regarding 
recycling and the proper disposal of an 
old control containing mercury in a 
sealed tube.

INSTALLATION

When Installing this Product…

1.

Read these instructions carefully. Failure 
to follow them could damage the product 
or cause a hazardous condition.

2.

Check the ratings given in the instructions 
and on the product to make sure the prod-
uct is suitable for your application.

3.

Installer must be a trained, experienced 
service technician.

4.

After installation is complete, check out 
product operation as provided in these 
instructions.

CAUTION

Electrical Shock or Equipment Damage 
Hazard.
Can shock individuals or short 
equipment circuitry.

Disconnect power supply before 
installation.

Location

Install the thermostat about 5 ft (1.5m) above 
the floor in an area with good air circulation at 
average temperature. Do not install the 
thermostat where it can be affected by:
— drafts or dead spots behind doors and in 

corners.

— hot or cold air from ducts.
— radiant heat from the sun or appliances.
— concealed pipes and chimneys.
— unheated (uncooled) areas such as an 

outside wall behind the thermostat.

Mounting Wallplate to Wall

Mount the T8775A,C wallplate, with the screws 
provided. See Fig. 1.

Fig. 1. Mounting wallplate to wall.

M19499

WALL ANCHORS (2)

WIRING HOLE

WALL PLATE

1 INCH SCREW (2)

1  WHEN USING WALL ANCHORS, DRILL 3/16 IN. HOLES
 

FOR DRYWALL, 7/32 IN. HOLES FOR PLASTER.

1

Summary of Contents for The Digital Round T8775A

Page 1: ...uct to make sure the prod uct is suitable for your application 3 Installer must be a trained experienced service technician 4 After installation is complete check out product operation as provided in these instructions CAUTION Electrical Shock or Equipment Damage Hazard Can shock individuals or short equipment circuitry Disconnect power supply before installation Location Install the thermostat ab...

Page 2: ...HEATING RELAY OR VALVE COIL M19513 1 1 M19514 HEATING RELAY OR VALVE COIL FAN RELAY 1 POWER SUPPLY PROVIDE DISCONNECT MEANS AND OVERLOAD PROTECTION AS REQUIRED 2 FACTORY INSTALLED JUMPER 1 2 W R Rc B O Y G 1 HEATING RELAY OR VALVE COIL COMPRESSOR CONTACTOR FAN RELAY M19515 1 POWER SUPPLY PROVIDE DISCONNECT MEANS AND OVERLOAD PROTECTION AS REQUIRED 2 FACTORY INSTALLED JUMPER 2 W R Rc B O Y G 1 2 1 ...

Page 3: ...Heat Cycle Rate Fahrenheit Celsius Indication Use DIP switch 3 to set the desired temperature indication See Table 2 Table 2 Temperature Indication Mounting Thermostat to Wallplate Fig 9 Mounting thermostat to wallplate OPERATION Setting SYSTEM and FAN Switches T8775C only System and fan settings are controlled manually by using the switches located at the top of the thermostat See Fig 10 M19497 F...

Page 4: ...n on 4 Lower the temperature setpoint below the room temperature 5 The flame will disappear from the display and the heat should turn off Cooling T8775C only CAUTION Low Temperature Hazard Operating at too low of an outdoor temperature may cause compressor damage Do not operate cooling if outdoor temperature is below 50 F 10 C Refer to manufacturer s recommendations NOTE If a call for cooling is m...

Page 5: ...uit pour s assurer que celui ci convient à l usage prévu 3 L installateur doit être un technicien d expérience ayant reçu une formation pertinente 4 Une fois l installation terminée vérifier le fonctionnement du produit en suivant les présentes instructions MISE EN GARDE Risque de choc électrique ou de dommages matériels Peut causer des blessures par choc électrique ou provoquer un court circuit C...

Page 6: ...nt avec un seul transformateur MF19499 CHEVILLES D ANCRAGE 2 TROU DE CÂBLAGE PLAQUE DE COMMUTATION VIS 1 PO 2 1 DANS LE CAS D UNE INSTALLATION AVEC CHEVILLES D ANCRAGE PERCER DES TROUS DE 3 16 PO SI LE MUR EST EN PLACOPLTRE OU DE 7 32 SI LE MUR EST EN PLTRE 1 ALIMENTATION FOURNIR AU BESOIN UN DISPOSITIF DE COUPURE ET UNE PROTECTION CONTRE LES SURCHARGES W R RELAIS DE CHAUFFAGE OU BOBINE DE VANNE M...

Page 7: ...e d énergie Microrupteurs Régler les cycles de chauffage ou l affichage de la température en degrés Celsius ou Fahrenheit à l aide des microrupteurs 1 2 3 au dos du thermostat Voir la Fig 8 Fig 8 Microrupteurs 1 2 1 RELAIS DE CHAUFFAGE OU BOBINE DE VANNE CONTACTEUR DU COMPRESSEUR RELAIS DE VENTILATEUR MF19517 1 ALIMENTATION FOURNIR AU BESOIN UN DISPOSITIF DE COUPURE ET UNE PROTECTION CONTRE LES SU...

Page 8: ... Système de chauffage Cycles par heure Micro rupteur 1 Micro rupteur 2 Vapeur gravité 1 On On Air chaud haute efficacité efficacité 90 eau chaude pompe à chaleur 3 Off On Air chaud au gaz ou mazout réglage en usine 6 Off Off Air chaud électrique 9 On Off Chaleur rayonnante dans les planchers Vérifier les cycles recommandés auprès du fabricant Affichage en Celsius ou Fahrenheit Microrupteur 3 Fahre...

Page 9: ... basses températures Le fonctionnement du système de refroidissement lorsque la température extérieure est trop basse peut endommager le compresseur Ne pas faire fonctionner le système en mode refroidissement si la température extérieure est inférieure à 10 C 50 F Lire les recommandations du fabricant REMARQUE Si un appel de refroidissement est effectué moins de cinq minutes après l arrêt du compr...

Page 10: ...T8775A C THE DIGITAL ROUND 69 1677EF 03 6 ...

Page 11: ...T8775A C THE DIGITAL ROUND 7 69 1677EF 03 ...

Page 12: ...ideoTechnologies Inc and its affiliates Tous droits réservés La marque de commerce Honeywell Home est utilisée avec l autorisation d Honeywell International Inc Ce produit est fabriqué par Resideo Technologies Inc et ses sociétés affiliées www resideo com Resideo Technologies Inc 1985 Douglas Drive North Golden Valley MN 55422 1 800 468 1502 69 1677EF 03 M S Rev 03 20 Imprimé aux États Unis ...