Configuration mode.
The configuration mode is used to set the RAK148D1 and RAK164D1
to match your heating/cooling system. These thermostats function
with up to 2-stage heat pump systems (RAK148D1 only).
To configure the RAK148D1 and RAK164D1, perform the
following steps:
Note:
Operation being set will blink in the display.
1.
Slide the
Function
switch to the
OFF
position.
2.
Remove the cover of the thermostat by gently pulling
on one of the corners.
3.
Simultaneously hold the
SW5
and
SW6
buttons in
for 5 seconds while the thermostat is in
OFF
mode.
4.
Press the
or
button to change settings within
each screen.
5.
Press the
SW6
button to advance to the next screen.
Note:
The
SW5
button will return you to the previous screen.
6.
To exit configuration mode, slide the
Function
switch to
Heat
or
Cool
.
Configuration Mode Settings
The setup screens for Configuration Mode are as follows:
1. Temperature Scale (F or C)—
Choose Fahrenheit or Celsius.
Press the
or
button
to select.
Press the
SW6
button to advance to the next screen.
2. Temperature Differential—
Stage 1—(1–9°F) (1–5°C)—
(Factory Setting is 2°F/1°C for
Each Stage)—
Set the number of
degrees between your “setpoint” temperature and your
“turn on” temperature for first stage.
Press the
or
button to set differential value.
Press the
SW6
button to advance to the next screen.
>
<
>
<
>
<