Troubleshooting tips.
No display
Check for 24 VAC at thermostat;
display is blank when 24 VAC is
not present.
System fan does not
Verify that wiring is correct.
come on properly
Thermostat turns on and
Adjust temperature differential
off too frequently
(see
Temperature Differential
,
Stage 1).
Fan runs continuously
Check
Fan Auto/On
switch. If set to
ON
position, fan will run continuously.
Room temperature is
Verify that wall hole is plugged
not correct
with putty or insulation; calibrate
thermostat (see
Configuration mode
).
Auxiliary heat not on
Adjust differential for 2nd stage
soon enough
(RAK148D1 only) heating, if required
(see
Configuration mode
).
Compressor doesn’t run
There is a 3 minute time delay and
or turn off immediately
a 3 minute minimum run time for
when changing function
the compressor when it turns on/off.
or setting
Fan doesn’t run or turn off
This is normal. On some models, the
immediately when changing
fan may have a 3 minute minimum
function or setting
run time/off time delay.
Problem not listed above
Press the
Reset
button once;
display will be refreshed.
Problem
Solution
Operating functions.
Heat
• In this mode, the thermostat
controls the heating system.
• Press the
or
buttons to set
the desired temperature.
>
<
Standby
Set
12
Summary of Contents for RAK148D1
Page 15: ...Notes 15 ...