Terminal designator descriptions.
R
— 24 VAC hot
C
— 24 VAC common
W — Aux. heat
Y
— Compressor
G
— Fan
B
— Heat active reversing
valve (RAK148D1 only)
Starting the thermostat.
CAUTION!
Do not use air conditioning when
the outdoor temperature is below 50 degrees. This can damage
your air conditioning system and cause personal injuries.
1.
Move the
Fan Auto/On
switch
to the
Auto
position.
2.
Move the
Function
switch to
Cool
or
Heat
, depending
on the season.
ROOM
Testing the thermostat.
Once the thermostat is installed, it should be thoroughly tested.
CAUTION!
Do not use air conditioning when
the outdoor temperature is below 50 degrees. This can damage
your air conditioning system and cause personal injuries.
Cool Test
1.
Slide
Function
switch to
Cool
mode.
2.
Adjust set temperature so it is 5
degrees below room temperature.
3.
Air conditioning should come on within a few seconds.
4.
Adjust the set temperature so it is 2 degrees above the room
temperature and the A/C should turn off.
Note:
There is a 3
minute time delay and a 3 minute minimum run time for the
compressor when it turns on/off. (On some models, the fan
may also have a 3 minute minimum run time/off time delay).
Cool
Heat
Off
10