Heat Test
1.
Slide
Function
switch to
Heat
mode.
2.
Adjust set temperature so it is 5
degrees above room temperature.
3.
Heat should come on within a few seconds.
4.
Adjust the set temperature so it is 2 degrees below the room
temperature and the heat should turn off.
Note:
There is a 3
minute time delay and a 3 minute minimum run time for the
compressor when it turns on/off. (On some models, the fan
may also have a 3 minute minimum run time/off time delay).
Note:
“Quick Heat Recovery” is activated each time the thermostat
is switched from
Off
or
Cool
modes to
Heat
mode. Electric heaters
are energized until the thermostat set point is reached. Heat pump
operation will resume at next call for heat (Heat pump only).
Fan Test
1.
Slide
Fan Auto/On
switch to
On
position.
2.
Indoor fan turns on.
3.
Slide
Fan Auto/On
switch to
Auto
position.
4.
Indoor fan turns off.
Cool
Heat
Off
Auto
On
Auto
On
Operating functions.
Off
• In this mode, the thermostat will not turn on the heating or
cooling devices (manual fan can operate).
•
Off
is also used to access
Setup
mode.
Cool
• In this mode, the thermostat
controls the cooling system.
• Press the
or
buttons to set
the desired temperature.
>
<
Standby
Set
11