FEED WATER

The water supply to the Reverse Osmosis system must 

have the qualities listed in the specifications. Municipal 

water supplies most often will have these qualities. 

Well water may need conditioning; have the water 

tested by a water analysis laboratory and get their 

recommendations for treatment.

IMPORTANT:

 For water with a hardness greater 

than 10 grains (at 6.9 pH) the use of a softener is 

recommended. Failure to install a softener will reduce 

the life of the Reverse Osmosis cartridge.

REVERSE OSMOSIS (RO) FAUCET

The RO product water faucet installs on the sink or on 

the countertop next to the sink. It may be installed in an 

existing sink spray attachment hole, or a hole may be 

drilled. Space is required underneath for tubing to and 

from the faucet, and for securing the faucet in place. All 

three faucet tubes are supplied already connected at 

one end to the faucet.

RO DRAIN CONNECTION

A suitable drain point and air gap (check your state 

and/or local codes) are needed for reject water from 

the Reverse Osmosis membrane cartridge.

Installation Instructions

INST

ALLA

TION INSTRUCTIONS

THINGS TO CHANGE BEFORE BEGINNING INSTALLATION

PREPARE FOR INSTALLATION

1. Before starting, close the hot and cold water shutoff valves.
2.  Temporarily place the filter assembly into planned location. Check position of items and space required for 

installation. Ensure tubes may be routed without kinking.

3. Remove the filter from planned location and set aside.

PLAN THE INSTALLATION

The Reverse Osmosis System should be installed under a sink.

Summary of Contents for PXRQ400T

Page 1: ...ademark license OWNER S MANUAL INSTALLATION INSTRUCTIONS REVERSE OSMOSIS Filtration System 49 6000289 Rev 0 08 22 GEA PXRQ400T SAFETY INFORMATION 3 SPECIFICATIONS 5 USING THE REVERSE OSMOSIS SYSTEM 6...

Page 2: ...s into every GE Appliances product and we think you will too Among other things registration of your appliance ensures that we can deliver important product information and warranty details when you n...

Page 3: ...other uses The system is typically installed at the point of use and must be installed as specified in the installation instructions Contact a plumbing professional if you are uncertain how to instal...

Page 4: ...e care when using pliers or pipe wrenches to tighten plastic fittings as damage may occur if over tightening occurs Do not install in direct sunlight or outdoors Locate the system in such a position a...

Page 5: ...ation be performed by a licensed plumber and do not permit the use of saddle valves Plumbing code 248 CMR of the Commonwealth of Massachusetts must be followed in these cases Product Water Testing The...

Page 6: ...lter cartridge The prefilter is a replaceable sediment cartridge containing activated carbon The prefilter reduces chlorine taste and odor in the feed water because CHLORINE DESTROYS THE REVERSE OSMOS...

Page 7: ...E Red 1 4 PE white 1 4 PE red DC adapter Water supply inlet Faucet with air gap Drain saddle BEFORE YOU BEGIN Read these instructions completely and carefully IMPORTANT Save these instructions for loc...

Page 8: ...attachment hole or a hole may be drilled Space is required underneath for tubing to and from the faucet and for securing the faucet in place All three faucet tubes are supplied already connected at on...

Page 9: ...or overtighten 5 Connect the existing cold water line to the male threaded portion of the water supply fitting and hand tighten Be careful not to cross thread or overtighten B OPTIONAL INSTALLATION A...

Page 10: ...ith installation 1 Test fit the two halves of the drain adapter onto the sink drain pipe about 6 inches above the Ptrap Make sure that the quick connect Q C fitting is toward the direction of the RO f...

Page 11: ...Tube Size 22 mm Hole Countertop Washer INSTALL THE FAUCET cont 1 If drilling is needed drill a 1 3 8 diameter hole in the mounting surface Be sure to use the proper procedure for drilling stone porce...

Page 12: ...Failure to follow these instructions may lead to future leaks When a 1 4 tube is fully engaged 11 16 of the tube has entered the fitting When a 3 8 tube is fully engaged 3 4 of the tube has entered th...

Page 13: ...white collet fitting on the Reverse Osmosis assembly 3 Cut tube square and to length 4 Insert all the way into the fitting 5 Pull on the tube to be sure it is held firmly in the fitting 1 4 RED TUBE...

Page 14: ...faucet and let water flow through the system for a 24 hour period Water flow will be a slow trickle at this time NOTE Do not consume water from the RO system until purging is complete 2 Close the Reve...

Page 15: ...e RO membrane Skip to step 3 if it is the first time installing the filter 1 Remove the Reverse Osmosis cartridge by turning clockwise 2 Discard the cartridges in a proper manner 3 Remove wrapping fro...

Page 16: ...ion or plug It is important that there are no dips loops or low spots in the drain line from the faucet air gap to the drain pipe Refer to Installation Instructions for proper drain connection If drai...

Page 17: ...Y 001 FQ400PT Replacement Filters 1 002 FQ400MT Replacement Membrane 1 003 WS02X23543 Front Panel 1 004 WS21X23541 DC Adapter 1 005 WS10X23542 Faucet with air gap 1 006 WS01X23608 Drain Saddle 1 007 W...

Page 18: ...18 49 6000289 Rev 0 NOTES Notes...

Page 19: ...ty is extended to the original purchaser and any succeeding owner for products purchased for home use within the USA If the product is located in an area where service by a GE Appliances Authorized Se...

Page 20: ...e Troubleshooting Tips and Care and Cleaning sections of this Use Care Manual Contact your local installer plumbing contractor or call GE Appliances Service and Support at 1 800 952 5039 NOTE Your ins...

Reviews: