Reverse Osmosis System:
Models: PXRQ400T
This system conforms to NSF/ANSI 58 for the specific performance claims as verified and substantiated by test data.
Non-potable Water Sources:
Do not attempt to use this product to make safe drinking water from non-potable water
sources. Do not use the system on microbiologically unsafe water, or water of unknown quality without an adequate
disinfection before or after the system. This system is certified for cyst reduction and may be used on disinfected water
that may contain filterable cysts.
Arsenic Reduction:
This system shall only be used for arsenic reduction on chlorinated water supplies containing
detectable residual free chlorine at the system inlet. Water systems using an inline chlorinator should provide a one
minute chlorine contact time before the reverse osmosis system.
Nitrate/Nitrite Test Kit:
This system is supplied with a nitrate/nitrite test kit. Product water should be monitored
periodically according to the instructions provided with the test kit.
Installations In the Commonwealth of Massachusetts:
The Commonwealth of Massachusetts requires installation
be performed by a licensed plumber and do not permit the use of saddle valves. Plumbing code 248-CMR of the
Commonwealth of Massachusetts must be followed in these cases.
Product Water Testing:
The Reverse Osmosis system contains a replaceable treatment component critical for the
effective reduction of total dissolved solids. Product water should be tested periodically to verify that the system is
performing properly.
Replacement of the reverse osmosis component:
This reverse osmosis system contains a replaceable component
critical to the efficiency of the system. Replacement of the reverse osmosis component should be with one of identical
specifications, as defined by the manufacturer, to assure the same efficiency and contaminant performance.
Specifications
Specifications
Supply water pressure limits . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .15- 60psi (0.1-0.4 MPa)
Supply water temperature limits . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .41-100 °F (5-38 °C)
Maximum total dissolved solids (TDS) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2000 ppm
Maximum water hardness @ 6.9 pH . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .10 gpg
Maximum iron, manganese, hydrogen sulfide . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 0
Chlorine in water supply (max. ppm) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2.0
Supply water pH limits (pH) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4-10
Product (quality) water, 24 hours
1
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .634 gal. (2,400 liters)
CARTRIDGE SPECIFICATIONS
Performance Data – Filtration System PXRQ400T Using Filter FQ400PT and FQ400MT
Rated/certified capacity = 240 gallon for FQ400PT
Performance data sheet is available at gewaterfilters.com