12
49-6000289 Rev. 0
Installation Instructions
HOW TO CONNECT TUBES
The Reverse Osmosis system includes push-in
fittings for quick tubing connection. Review the
following instructions before connecting the tubes in
the next step. Failure to follow these instructions may
lead to future leaks.
CUT TUBES TO LENGTH
1. Use a sharp cutter or knife to cut the end of tubing.
Always cut the tubing end square and smooth, with
no nicks or rough spots.
the end of this manual.
Push-in Fitting
Tube
Tube Partially Engaged
Collet
O-Ring
Tube Fully Engaged
Collet
O-Ring
Tubing
Collet (depress to
remove tubing)
NOTE:
Tubing lengths should allow the RO assembly
to be moved for servicing.
2. Inspect the tube up to 1” from the end to be sure
there are no nicks, scratches or other rough spots.
If needed, cut the tubing again.
CONNECT TUBES
1. Push tubing through collet, until it engages the
o-ring. Continue pushing until the tube bottoms out
against the back of the fitting. Do not stop pushing
when the tube engages the o-ring. Failure to follow
these instructions may lead to future leaks. When
a 1/4” tube is fully engaged, 11/16” of the tube
has entered the fitting. When a 3/8” tube is fully
engaged, 3/4” of the tube has entered the fitting.
Mark tube with a piece of tape or marker.
2. If additional tubing is required, see parts list at the
end of this manual.
the end of this manual.
Push-in Fitting
Tube
Tube Partially Engaged
Collet
O-Ring
Tube Fully Engaged
Collet
O-Ring
Tubing
Collet (depress to
remove tubing)
MAKING TUBING CONNECTIONS
Drain
1. Use the red tube (1/4" from Reverse Osmosis
assembly to faucet and 3/8" for faucet to saddle
valve)
2. Fully fasten onto faucet spigot
3. Locate and insert tube into "Drain" fitting, adjusting
length by cutting appropriately.
Out
1. Use the white tube (3/8" from inlet three way ball
valve to Reverse Osmosis assembly and 1/4" from
Reverse Osmosis assembly to faucet)
2. Insert firmly into "Out" fitting on the system
3. Cut to appropriate length.
HOW TO CONNECT TUBES (cont.)
TO DISCONNECT TUBES (If necessary)
1. Push the collet inward with a finger tip.
2. Continue holding collet inward while pulling the
tubing out.
the end of this manual.
Push-in Fitting
Tube
Tube Partially Engaged
Collet
O-Ring
Tube Fully Engaged
Collet
O-Ring
Tubing
Collet (depress to
remove tubing)
INST
ALLA
TION INSTRUCTIONS