GE PXRQ400T Owner'S Manual & Installation Instructions Download Page 17

49-6000289  Rev. 0

17

PARTS LIST

Parts List

No. Part Number Part Name

QTY

001

FQR400PT Replacement 

fil

ters 

1

002

FQR400MT Replacement membrane 

1

003 WS02X23543 Front panel

1

004 WS21X23541 DC Adapter

1

005 WS10X23542 Faucet with air gap

1

006 WS01X23608 Drain saddle

1

007 WS22X23604 Water Supply inlet

1

008 WS07X23603 3/8" PE tube 1.5 meter - white

1

009 WS07X23602 1/4" PE tube L:1.5m - white

1

010 WS07X23605 1/4" PE tube L:1.5m - red

1

011 WS01X23606 3/8" clip, POM, blue

2

012 WS01X23607 1/4" clip, POM, blue

1

1

2

4

3

5

6

7

8

9

10

12

11

Parts Catalog

No.

Part Number

Part Name

QTY

001

FQ400PT

Replacement Filters

1

002

FQ400MT

Replacement Membrane

1

003

WS02X23543

Front Panel

1

004

WS21X23541

DC Adapter

1

005

WS10X23542

Faucet with air gap

1

006

WS01X23608

Drain Saddle

1

007

WS22X23604

Water Supply Inlet

1

008

WS07X23603

3/8" PE tube 1.5 meter - white

1

009

WS07X23602

1/4" PE tube L:1.5m - white

1

010

WS07X23605

1/4" PE tube L:1.5m - red

1

011

WS01X23606

3/8" clip, POM, blue

2

012

WS01X23607

1/4" clip, POM, blue

1

Summary of Contents for PXRQ400T

Page 1: ...ademark license OWNER S MANUAL INSTALLATION INSTRUCTIONS REVERSE OSMOSIS Filtration System 49 6000289 Rev 0 08 22 GEA PXRQ400T SAFETY INFORMATION 3 SPECIFICATIONS 5 USING THE REVERSE OSMOSIS SYSTEM 6...

Page 2: ...s into every GE Appliances product and we think you will too Among other things registration of your appliance ensures that we can deliver important product information and warranty details when you n...

Page 3: ...other uses The system is typically installed at the point of use and must be installed as specified in the installation instructions Contact a plumbing professional if you are uncertain how to instal...

Page 4: ...e care when using pliers or pipe wrenches to tighten plastic fittings as damage may occur if over tightening occurs Do not install in direct sunlight or outdoors Locate the system in such a position a...

Page 5: ...ation be performed by a licensed plumber and do not permit the use of saddle valves Plumbing code 248 CMR of the Commonwealth of Massachusetts must be followed in these cases Product Water Testing The...

Page 6: ...lter cartridge The prefilter is a replaceable sediment cartridge containing activated carbon The prefilter reduces chlorine taste and odor in the feed water because CHLORINE DESTROYS THE REVERSE OSMOS...

Page 7: ...E Red 1 4 PE white 1 4 PE red DC adapter Water supply inlet Faucet with air gap Drain saddle BEFORE YOU BEGIN Read these instructions completely and carefully IMPORTANT Save these instructions for loc...

Page 8: ...attachment hole or a hole may be drilled Space is required underneath for tubing to and from the faucet and for securing the faucet in place All three faucet tubes are supplied already connected at on...

Page 9: ...or overtighten 5 Connect the existing cold water line to the male threaded portion of the water supply fitting and hand tighten Be careful not to cross thread or overtighten B OPTIONAL INSTALLATION A...

Page 10: ...ith installation 1 Test fit the two halves of the drain adapter onto the sink drain pipe about 6 inches above the Ptrap Make sure that the quick connect Q C fitting is toward the direction of the RO f...

Page 11: ...Tube Size 22 mm Hole Countertop Washer INSTALL THE FAUCET cont 1 If drilling is needed drill a 1 3 8 diameter hole in the mounting surface Be sure to use the proper procedure for drilling stone porce...

Page 12: ...Failure to follow these instructions may lead to future leaks When a 1 4 tube is fully engaged 11 16 of the tube has entered the fitting When a 3 8 tube is fully engaged 3 4 of the tube has entered th...

Page 13: ...white collet fitting on the Reverse Osmosis assembly 3 Cut tube square and to length 4 Insert all the way into the fitting 5 Pull on the tube to be sure it is held firmly in the fitting 1 4 RED TUBE...

Page 14: ...faucet and let water flow through the system for a 24 hour period Water flow will be a slow trickle at this time NOTE Do not consume water from the RO system until purging is complete 2 Close the Reve...

Page 15: ...e RO membrane Skip to step 3 if it is the first time installing the filter 1 Remove the Reverse Osmosis cartridge by turning clockwise 2 Discard the cartridges in a proper manner 3 Remove wrapping fro...

Page 16: ...ion or plug It is important that there are no dips loops or low spots in the drain line from the faucet air gap to the drain pipe Refer to Installation Instructions for proper drain connection If drai...

Page 17: ...Y 001 FQ400PT Replacement Filters 1 002 FQ400MT Replacement Membrane 1 003 WS02X23543 Front Panel 1 004 WS21X23541 DC Adapter 1 005 WS10X23542 Faucet with air gap 1 006 WS01X23608 Drain Saddle 1 007 W...

Page 18: ...18 49 6000289 Rev 0 NOTES Notes...

Page 19: ...ty is extended to the original purchaser and any succeeding owner for products purchased for home use within the USA If the product is located in an area where service by a GE Appliances Authorized Se...

Page 20: ...e Troubleshooting Tips and Care and Cleaning sections of this Use Care Manual Contact your local installer plumbing contractor or call GE Appliances Service and Support at 1 800 952 5039 NOTE Your ins...