![GE PVB94 Installation Instructions Manual Download Page 7](http://html1.mh-extra.com/html/ge/pvb94/pvb94_installation-instructions-manual_4092211007.webp)
7
Installation Preparation
VENTING OPTIONS
• The downdraft vent is shipped with the
discharge outlet pointing straight down
and can be changed to the left or right
side.
• The blower outlet is sized for 3-1/4" x 10"
and can be transitioned to 6" round.
Side-to-Side Adjustments:
The entire blower mounting plate can be
adjusted 3-1/2" to the left or right. This
will help to align vent discharge to house
ductwork.
Discharge Direction
The blower assembly may be removed and turned
90° for a left- or right-side discharge.
• A left or right 90° direction adjustment should be
performed before dropping into the countertop
opening.
To change to a left or right discharge:
• Remove the 4 screws holding the blower and the
mounting plate assembly to the downdraft vent.
Retain screws.
• Remove blower assembly; turn it over to access the
4 nuts holding the blower to the mounting plate.
Remove the nuts.
Discharge Down
$V6XSSOLHG
Loosen Screws
to Adjust
3-1/2" to
Left or Right
IMPORTANT:
Do not lift motor by the power cable.
• Turn the blower to the left or right discharge
direction and reinstall the 4 nuts.
• Reinstall blower and mounting plate with original
screws.
• The hood must vent down or to the left when in-
stalled with a GE or Monogram gas cooktop to avoid
interference with the inlet of the gas cooktop.
17-1/4"
16-3/8"
10-5/16"
4-1/4"
4-1/4"
4-1/4"
Discharge Down
$V6XSSOLHG
Discharge Left
Discharge Right