Installation Preparation

 

IMPORTANT

(Please read carefully.)

The power cord of this appliance is equipped with 

DWKUHHSURQJJURXQGLQJSOXJZKLFKPDWHVZLWK

a standard three-prong grounding wall receptacle 

to minimize the possibility of electric shock. The 

customer should have the wall receptacle and 

FLUFXLWFKHFNHGE\DTXDOL¿HGHOHFWULFLDQWRPDNH

sure the receptacle is properly grounded and has 

correct polarity.
• Where a standard two-prong wall receptacle is 

encountered, it is the personal responsibility and 

obligation of the customer to have it replaced 

with a properly grounded three-prong wall 

receptacle.

Do not, under any circumstances, cut or remove 
the third (ground) prong from the power cord.

Do not use an extension cord or adapter plug with 

this appliance. Follow National Electrical Code or 

prevailing local codes and ordinances.
Location of Rating Label: on front of chassis of 

vent system.

This downdraft vent must be supplied with 120V, 

60 Hz. and connected to an individual, properly 

grounded branch circuit, protected by a 15- or 

20-ampere circuit breaker or time-delay fuse.
A properly grounded 3-prong receptacle should be 

located within reach of the vent’s two-foot power 

cord. 
• 

Gas Cooktops

If this vent is installed in combination with a GE or 

Monogram gas cooktop, it may operate from the 

same duplex outlet.

• 

Electric Cooktops

If this vent is installed in combination with a GE 

or Monogram electric cooktop, the vent must 
operate from a separate 120V outlet.

Locate the receptacle inside the cabinet on the right 

VLGHZDOOVHHLOOXVWUDWLRQ7KHUHFHSWDFOHFDQQRWEH

placed on the back of the cabinet wall where it may 

interfere with the downdraft plenum. 
The downdraft vent power cord is to be routed 

beneath the cooktop and routed away from heat 

generated by the cooktop.
Ensure that the cooktop is installed per 

manufacturer’s installation instructions.

POWER SUPPLY

Locate the Gas or Electrical 

Connection Only Within the 

Shaded Area

DO NOT Locate 

Gas or Electrical 

Connections within 

this Area

FXWRXWZLGWKIRUPRGHOV

FXWRXWZLGWKIRUPRGHOV

29-1/2" 

12" 

Electrical 

Outlet 12" 

Above 

Cabinet 

Floor

Summary of Contents for PVB94

Page 1: ...1 Installation Instructions Downdraft Vent Systems PVB94 PVB98 ZVB30 ZVB36 31 10728 8 11 14 GE...

Page 2: ...stalled and grounded WARNING Improper grounding can result in a risk of electric shock Consult a qualified electrician if the grounding instructions are not completely understood or if doubt exist as...

Page 3: ...WKH PHULFDQ 6RFLHW for Heating Refrigeration and Air Conditioning QJLQHHUV 6 5 DQG WKH ORFDO FRGH DXWKRULWLHV When cutting or drilling into wall or ceiling do not damage electrical wiring and other h...

Page 4: ...and connected to an individual properly grounded branch circuit protected by a 15 or 20 ampere circuit breaker or time delay fuse A properly grounded 3 prong receptacle should be located within reach...

Page 5: ...Optional accessory for indoor remote location of the blower motor assembly Use this kit when the blower and motor assembly will be located RXWVLGH RI WKH FDELQHW VXFK DV EHORZ WKH FDELQHW RRU 9 3 45...

Page 6: ...UP WKH FOHDUDQFHV needed within the cabinet the exhaust vent direction and the alignment of the exhaust vent with the ducting If needed for clearance or duct hookup alignment reposition the location...

Page 7: ...o the countertop opening To change to a left or right discharge Remove the 4 screws holding the blower and the mounting plate assembly to the downdraft vent Retain screws Remove blower assembly turn i...

Page 8: ...ides The front of the opening must clear the front support rail on the cabinet and the rear of the opening must clear the rear support of the cabinet Chamfer all exposed edges of decorative laminate t...

Page 9: ...t arrangement under concrete slab PVC duct should be used if installing under a poured concrete slab PREPARE FOR DUCTWORK Determine the best route for ductwork it can be routed in a variety of ways de...

Page 10: ...LV sitting on top of the countertop C Secure the screws for the stabilizing brackets to the cabinet back and side walls D RQ UP WKH YHQW V VWHP LV SOXPE DQG VTXDUH with the cabinetry Installation Ins...

Page 11: ...nt the remote switch on the countertop such that the switch connectors stay located in the 1 2 dia hole Stick adhesive wire clamp near the 1 2 dia hole and attach the loose wire with a wire tie WARNIN...

Page 12: ...Adjust the blower by pressing HIGHER or LOWER To lower the vent press the ON OFF pad NOTE It is not necessary to turn the fan OFF before lowering the vent The fan will automatically WXUQ R ZKHQ WKH YH...

Reviews: