– 52 –
DOOR
MOTOR TO N
L1- TO N
TERMINALS
SWITCH CONTACTS
BROIL TO N
BAKE TO N
120 VAC locking or unlocking
120 VAC ALL THE TIME
120 VAC when in BAKE mode
VOLTAGE
120 VAC when in BROIL mode
Note: Temperature/Mode selection necessary for
operation of relay contacts.
Note: Voltage must be present across terminals
L1 to N for control to operate. Transformer
primary is 150
Ω
to 200
Ω
measured L1 to (N)
with power removed.
*If oven light is not working, make the following
checks:
•
Check oven light bulb.
•
Light is to come on when door is opened.
Check voltage across light socket terminals. It
should read 120 VAC. If 0 volts, check jamb
switch and wiring.
•
Light is to come on when control light pad is
pressed. RLY105 should click. Check voltage
from P104-7 to L1. It should read 120 VAC. If 0
volts, check oven light keypad using
ohmmeter test. If keypad is good, replace the
control.
Oven Calibration
Testing has shown that this oven has the best
cooking performance at a control setting of 350°F
(177°C) when the average center oven
temperature is between:
All Gas Range - 350°F and 390°F (177°C and
199°C).
Dual Fuel Range - 340°F and 380°F (171°C and
193°C).
Customers may change the average center oven
temperature by ± 35°F (± 2°C) to satisfy their own
cooking needs.
To change:
•
Press and hold BAKE and BROIL pads until
SF appears in display.
•
Press BAKE pad to enter oven calibration
mode. 00 appears if oven calibration has not
been changed previously. If oven calibration
has been changed previously, a temperature
between ± 35°F (± 2°C) will be displayed.
•
Press increase or decrease pads to change
average oven temperature.
•
Press START pad to return to Time of Day.
Dual Fuel Range
Relay Contacts Operation Test and
Control Voltage Check
All Gas Range
L1-N
COM to N
L1-BA-DLD
*Light-L1
COM to MDL
L1 to CF
TERMINALS
CIRCUIT TERMINALS OHMS
120 VAC ALL THE TIME.
120 VAC ALL THE TIME.
240 VOLTS when oven is not
calling for heat (BAKE, CONV.
and BROIL relay contacts open).
120 VOLTS when light is on.
120 VOLTS not locking or
unlocking, door closed.
120 VOLTS when oven door is
closed and CONV. BAKE and
Conv. Roast not operating.
VOLTAGE
Oven sensor
Temp.
Door
Unlatched
Door Latched
6 to 8
3 to 5
4 to 5
4 to 5
3 to 5
1100
Ω
@ Rm
2650
Ω
@ 865°F
0
Ω
open
0
Ω
open
TERMINALS
VOLTAGE
Summary of Contents for Profile J2S968 SERIES
Page 57: ... 57 All Gas Range Schematic with Convection Fan JGS968 ...
Page 58: ... 58 All Gas Range Wiring Diagram with Convection Fan JGS968 ...
Page 59: ... 59 Dual Fuel Range Schematic J2S968 ...
Page 60: ... 60 Dual Fuel Range Wiring Diagram J2S968 ...
Page 61: ... 61 Notes ...
Page 62: ... 62 Notes ...
Page 63: ... 63 Notes ...