49-2000658 Rev. 0
13
PREPARING CABINET: BELOW WALL OVENS
INSTALLATION BELOW A SINGLE OVEN
INSTALLATION BELOW A DOUBLE OVEN
■
When installed, the front face of the warming
drawer will be nearly flush with cabinetry doors or
drawer fronts.
■ Drawer overlaps will conceal cut edges on all sides
of the opening.
The rough opening for the drawer must be:
— Depth: 23
1
/
2
” minimum from inside back to front
of cabinet frame.
— Width: 25
1
/
2
” for 27” wide models
28
1
/
2
” for 30” wide models.
— Height: 9
1
/
4
”
— Allow 2” minimum between oven and drawer
cutouts for clearance of overlaps
NOTE:
If you are installing in frameless cabinets, it
may be necessary to install 1/2” wide cleats to accept
drawer mounting screws. See drawer to find exact
locations of mounting screws.
When installed under a wall oven:
Warming drawers are suitable for installation below
only certain specified wall oven models. See the
label attached to the top of the warming drawer for
suitable models.
NOTE:
Electrical receptacle can be installed as shown
for countertop installations. Do not install receptacle
above the top of the warming drawer cutout.
INST
ALLA
TION INSTRUCTIONS
Installation Instructions
23
1
/
2
”
Min.
2x2 or 2x4
anti-tip block
against rear
wall 9” from
floor to bottom
of block
1" Min. above toekick
or adjust to oven
installation height
A
2" Min.
Allow 5/8”
overlap on
all sides
B
Oven
cutout
NOTE:
Additional clearance between cutouts may be
required. Check to be sure that oven supports above
the warming drawer location do not obstruct the
required interior 23
1
/
2
” depth and 9
1
/
4
” height.
Dimension A Dimension B
27" Drawer
25
1
/
2
”
26
3
/
4
”
30" Drawer
28
1
/
2
”
29
3
/
4
”
9"
9
1
/
4
"
10
1
/
2
"
23
1
/
4
"
CAUTION
IN CANADA, THE WALL
OVEN IS ONLY APPROVED
FOR INSTALLATION WITH
A BOTTOM CUTOUT AT A
MINIMUM OF 32.5” FROM
THE FLOOR.
NOTE:
Additional clearance between
cutouts may be required. Check to be sure
that oven supports above the warming
drawer location do not obstruct the required
interior 23
1
/
2
” depth and 9
1
/
4
” height.
CAUTION
IN CANADA, THIS DRAWER
IS NOT APPROVED FOR
INSTALLATION UNDER A
DOUBLE OVEN.
2" Min
1" Min. above
toekick
2x2 or 2x4
anti-tip block
against rear wall
9” from floor to
bottom of block
23
1
/
2
”
Min.
Allow 5/8” overlap
on all sides
A
9"
9
1
/
4
"
B
10
1
/
2
"
23
1
/
4
"
Oven
cutout
1" = 2.5 cm; 1' = 0.3 m
Summary of Contents for PKW7000 Series
Page 17: ...49 2000658 Rev 0 17 Notes ...
Page 37: ...49 2000658 Rév 0 17 Notes ...