7. Technical Specifications
PHASOR XS Operating Manual
Page 93
7.3 Environmental
Tests
Per Mil-Std-810F
Cold Storage
-20°C for 72 hrs, 502.4
Procedure I
Cold Operation
0°C for 16 hrs, 502.4
Procedure II
Heat Storage
+70°C for 48 hrs, 501.4
Procedure I
Heat Operation
+50°C for 16 hrs, 501.4
Procedure II
Damp Heat / Humidity
(storage)
10 Cycles:
10hrs at +65°C down to
+30°C, 10 hrs at +30°C up to
+65°C, Transition within 2 hrs,
507.4
Temperature Shock
3 Cycles:
4 hrs at –20°C up to +70°C,
4 hrs at +70°C, Transitions
within 5 mins. 503.4
Procedure II
Vibration
514.5-5 Procedure I, Annex
C, Figure 6,
General exposure: 1hr each
axis
Shock
6 cycles each axis, 15g, 11ms
half sine, 516.5 Procedure I
Loose Cargo
514.5 Procedure II
Transit Drop
(packaged for shipment)
516.5 Procedure IV, 26 drops
IP54 / IEC529 … Dust Proof / dripping water proof as per IEC
529 specifications for IP54 classification
7.4 Phased
Array
Probes
Product
Code
Frequency
MHz
Element
Cable
Length
Count
Aperture
Elevation
Pitch
mm
2
inch
2
mm
inch
mm
inch
m
ft
L8U84
2
8
8 x 9
.31 x .35
9
.35
1
.039
2
6.5
L8U96
4
16
8 x 9
.31 x .35
9
.35
0.5
.020
2
6.5
EUN75
5
32
16 x 10
.63 x .39
10
.39
0.5
.020
2
6.5
L99HK
5
16
16 x 10
.63 x .39
10
.39
1
.039
2
6.5
L99KO
2.25
16
16 x 13
.63 x .51
13
.51
1
.039
2
6.5
L99LQ
2.25
16
24 x 19
.94 x .75
19
.75
1.5
.059
2
6.5
L99JM
5
64
64 x 10
.2.5 x .39
10
.39
1
.039
2
6.5
GE Inspection Technologies: productivity through inspection solutions GE Inspection Technologies provides technology-driven inspection solutions that
deliver productivity, quality and safety. We design, manufacture and service Ultrasonic, Remote Visual, Radiographic and Eddy Current equipment and
systems. Offering specialized solutions that will help you improve productivity in your applications in the Aerospace, Power Generation, Oil & Gas, Automo-
tive or Metals Industry. Contact your GE Inspection Technologies representative or visit www.ge.com/inspectiontechnologies for more information.
Summary of Contents for Phasor CV
Page 6: ...Contents Page 4 PHASOR XS Operating Manual...
Page 16: ...1 Phased Array Operation Keypad Menus and Displays Page 14 PHASOR XS Operating Manual...
Page 24: ...2 Setting Up for Phased Array Measurement Page 22 PHASOR XS Operating Manual...
Page 86: ...5 Making Conventional Measurements Page 84 PHASOR XS Operating Manual...
Page 92: ...6 Storing Data Sets and Generating Reports Page 90 PHASOR XS Operating Manual...
Page 96: ...7 Technical Speci cations Page 94 PHASOR XS Operating Manual...