background image

1.2.1

Power On/Off and User-defined Buttons

Power On/Off Button Operation

Button

Action

Power on

Touch the button for at least ½ second.

If powering up after input power has been restored, the LED blinks blue

while the unit is booting and is solid green when the unit is up and running.

If the system has been shut down, and input power not removed, the LED

immediately turns solid green.

Power off

Touch the button briefly (between 100 ms and 4 seconds).

The LED remains green while the unit is shutting down and displays as

white when the unit is powered down.

Force

shutdown

Touch the button for at least 4 seconds. The LED turns white when the unit

is powered down.

Caution

Use this option only if the
operating system is
non-responsive.

The LED displays solid red to indicate a fault, including over-temperature condition.

User-defined Button and LED Operation

Button

Operation

Menu

User-defined button and white LED.

GE-IP FpBtn driver illuminates LED and allows user to select

Windows application to open or keycode to select when button

touched.

Plus

Minus

16

GFK-2898B

PACSystems 19" RXi Display

For public disclosure

Summary of Contents for PACSystems ICRXIDIXNE19LCTA

Page 1: ...GFK 2898B PACSystems 19 RXi Display User Manual Jan 2016 For public disclosure...

Page 2: ...included therein as is and without warranty of any kind expressed or implied including but not limited to any implied statutory warranty of merchantability or fitness for particular purpose For furthe...

Page 3: ...rotocol FG Frame Ground GND Ground HDD Hard Disk Drive IPC Industrial PC mPCIe Miniature PCI Express RAM Random Access Memory RTC Real Time Clock SATA Serial ATA SD Secure Digital SELV Safety Extra Lo...

Page 4: ...esult in personal injury or death Caution Indicates a procedure condition or statement that if not strictly observed could result in damage to or destruction of equipment Attention Indicates a procedu...

Page 5: ...nical Support Email support ip ge com Customer Care Email customercare ip ge com Primary language of support English Europe the Middle East and Africa Online Technical Support http support ge ip com P...

Page 6: ...Notes 6 GFK 2898B PACSystems 19 RXi Display For public disclosure...

Page 7: ...own the Computer 23 2 4 1 Disabling Operating System Shutdown 24 3 Hardware Installation 25 3 1 Mounting and Installation Guidelines 25 3 2 Grounding 25 3 3 Mounting and Installation 26 3 3 1 Removal...

Page 8: ...Government Regulations 43 Index 45 8 GFK 2898B PACSystems 19 RXi Display For public disclosure...

Page 9: ...orporates RXi Box IPC processor hardware to create a system that lowers total cost ownership with seamless replacement of either the processor or display component and provides for powerful upgrades t...

Page 10: ...19 RXi Display Front View 19 RXi Display Rear View 10 GFK 2898B PACSystems 19 RXi Display For public disclosure...

Page 11: ...lock RTC accuracy Maximum drift of 2 seconds day at 25 C 77 F Video Standard 15 pin VGA connector Maintenance ports Intended only for temporary connection Two Type A USB 2 0 SD standard card slot Dual...

Page 12: ...ve Strength 400 MPa Electrical Grounding Frame ground FG internally connected to signal ground Physical Material Aluminum bezel Enclosure Rating UL NEMA Type 1 Depth to Panel 10 16 mm 0 4 in Panel Cut...

Page 13: ...emporarily become conductive due to occasional condensation 1 Applies only to 19 Displays with solid state hard drive 2 For ambient temperatures greater than 50 C 122 F the unit must be installed in a...

Page 14: ...format TFT LCD display Power on off and three user defined capacitive touch buttons with LED indicators Status indicators for disk activity and over temperature Status indicators for Wi Fi Bluetooth...

Page 15: ...Menu Plus Minus Power On Off Overtemp SATA Drive Activity Bluetooth Wi Fi WWAN Input Power Ethernet 1 Ethernet 2 VGA USB 1 USB 2 Serial RS 232 Connector Panel RXi Display Features Overview GFK 2898B...

Page 16: ...remains green while the unit is shutting down and displays as white when the unit is powered down Force shutdown Touch the button for at least 4 seconds The LED turns white when the unit is powered do...

Page 17: ...te solid Connected to WWAN optional mPCIe card 1 2 3 Ethernet Port LEDs Each Ethernet port has two LED indicators ACTIVITY and LINK LED Status Indicator State Description Activity Activity LED Link LE...

Page 18: ...Notes 18 GFK 2898B PACSystems 19 RXi Display For public disclosure...

Page 19: ...you should action be necessary After unpacking the RXi Display record all serial numbers Serial numbers are required if you need to contact Customer Care during the warranty period All shipping conta...

Page 20: ...the building installation wiring Note The product is supplied with a Phoenix Contact part number 1827716 power terminal block plug Phoenix Contact part number 1851245 spring loaded quick release power...

Page 21: ...onal use During power up you should see the normal operating system starting displays on the monitor During normal power up and operation the Power On Off status indicator displays as follows Power On...

Page 22: ...onnectors and Cabling 2 When prompted by the operating system restart the RXi Display 3 Connect the RXi Display to the Ethernet network 2 3 1 Pinging TCP IP Ethernet Interfaces on the Network Most nod...

Page 23: ...RXi Display Refer to the table Power On Off LED Status Indicator 1 Touch Power On Off briefly between 100 ms and 4 seconds or select Shut Down from the Windows Start menu This provides a controlled sh...

Page 24: ...e to 4 seconds using Windows 7 settings To change the Off button touch time using Windows 1 From the Start menu select Control Panel 2 Select Hardware and Sound section if displayed 3 Select Power Opt...

Page 25: ...ation To avoid impacting mechanical reliability and signal quality cable installation must comply with the minimum bend radius specified by the cable manufacturer 3 2 Grounding The following guideline...

Page 26: ...replace if necessary 2 Swing the eight levers on the back of the RXi Display to their retracted position held in place by a ball plunger 3 From the front of the enclosure tilt the RXi Display into the...

Page 27: ...eir retracted position held in place by a ball plunger Caution Be careful to not drop the unit when tilting it forward to remove it from the enclosure 3 Insert a thin blade from the front between the...

Page 28: ...Notes 28 GFK 2898B PACSystems 19 RXi Display For public disclosure...

Page 29: ...specified may present a high risk of fire or explosion Warning The battery may explode if mistreated Do not recharge disassemble heat above 100 C 212 F or incinerate Caution To avoid damage from elect...

Page 30: ...e the RTM chassis with interior lid on a static safe surface 4 Remove the four Phillips head screws that secure the interior lid to the RTM chassis and lift off the interior lid 5 Remove the RTC batte...

Page 31: ...d snapped into place 7 Replace and secure the interior lid using four Phillips head screws 8 Reconnect the internal power cable 9 Reattach the two RTM sections together without pinching the internal p...

Page 32: ...from the display panel 3 Loosen the four captive screws that are holding the two RTM sections together and gently separate without stretching the internal power cable Disconnect the internal power ca...

Page 33: ...he standards identified in Appendix A 2 Can be permanently connected while the system is running 3 Intended only for temporary connection 5 1 Input Power The RXi Display requires the following power i...

Page 34: ...ry 5e twisted pair cable between each node and a switch hub or repeater Attention For all three types shielded twisted pair STP cable is required to maintain CE compliance 10BASE T Two pairs of wire a...

Page 35: ...J 45 female connector with the following pin assignments Attention Shielded cable is required to maintain CE compliance Serial RS 232 Port Pin Assignments RJ 45 Pin Signal Description 8 0 V 0 V 7 NC N...

Page 36: ...board mouse serial communications or data storage device Attention Double shielded cable that complies with USB 2 0 is required Note These USB ports are defined as maintenance ports and are intended t...

Page 37: ...a 1 1 A self resetting fuse on the 5 V signal pin 9 5 6 Secure Digital Card Slot The RXi Display accommodates a user supplied Secure Digital SD card for auxiliary storage The SD card slot is a mainten...

Page 38: ...Notes 38 GFK 2898B PACSystems 19 RXi Display For public disclosure...

Page 39: ...der driver VIA graphics driver IDT audio codec driver Custom GE IP drivers Qty 6 GE IP FpBtn driver for user defined buttons optional 6 2 Overtemperature Shutdown Recovery All Models If the RXi Displa...

Page 40: ...Notes 40 GFK 2898B PACSystems 19 RXi Display For public disclosure...

Page 41: ...Information Technology Equipment and Industrial Control Equipment Certification by Underwriter s Laboratories to UL CSA 60950 1 and UL 508 and CAN CSA C22 2 NO 142 1987 Electromagnetic Compatibility D...

Page 42: ...unity EN 61131 2 Zone B ITE Immunity EN 55024 CISPR 24 Electrostatic Discharge EN 61000 4 2 8 0 kV Air 4 0 kV contact RF Susceptibility EN 61000 4 3 10 Vrms m 0 8 to 1 0 GHz 3 Vrms m 1 0 to 2 0 GHz 1...

Page 43: ...gy and if not installed and used in accordance with the instruction manual may cause harmful interference to radio communications Operation of this equipment in a residential area is likely to cause h...

Page 44: ...Notes 44 GFK 2898B PACSystems 19 RXi Display For public disclosure...

Page 45: ...ports 34 Ethernet media 34 F Features 9 Mounting 26 User 14 Federal Communications Commission FCC Notice 43 G Government regulations 43 Grounding 25 H Humidity 13 I Indicators 14 Ethernet 17 Ethernet...

Page 46: ...ion port 35 Shock 13 Shutting Down the Computer 23 Specifications 11 19 RXi Display 12 Environment 13 General 11 Standards 41 EMC 42 Startup Initial 19 Intial 20 Status 17 Status Indicators 16 SW1 1 3...

Page 47: ......

Page 48: ...Automation Controls from GE 1 800 433 2682 1 434 978 5100 www geautomation com GFK 2898B For public disclosure...

Reviews: