E4H Series
Operation & Maintenance Manual
24
6. TROUBLESHOOTING
This troubleshooting guide can assist you in identifying common operating problems
you may experience with your machine. The operator can easily correct many of
these problems; however, for those that persist or are not understood, you should
contact the GE Water & Process Technologies technical support team. Have the
following information available when calling the GE Water & Process Technologies
technical support team:
•
Machine installation date.
•
Model number (found on right-hand side of front panel).
•
Serial number (found on right-hand side of front panel).
•
Daily Log Sheets.
•
Detailed description of problem.
Table 5. Troubleshooting Guide
Symptom (Alarm)
Possible Cause
Remedies
Insufficient feed water
pressure
Increase the feed pressure, open the
inlet/feed valve, check for
restrictions, and consider installing a
feed water boost pump.
Clogged pre-filter
Replace the pre-filters.
Low inlet pressure
(low inlet alarm)
Solenoid valve not
opening
Clean or replace the solenoid valve.
Clean air line for adequate pressure.
Check regulator for correct
operation and setting.
High flow rates
Close the orifice bypass valve, check
the permeate and concentrate flow
rates and adjust if necessary.
Excessive permeate flow may
indicate improper interconnector
installation.
Pump discharge screen
(low primary pressure)
Inspect and clean.
Dirty or fouled
membranes
(low final pressure)
Clean the membranes.
Warm operating
conditions
Correct temperature.
Pump rotating
backwards
(3-phase power only)
Switch any two 3-phase leads to the
motor starter.
Low operating
pressure
Pump not operating
correctly
See pump instructions.
Summary of Contents for Osmonics E4H Series
Page 36: ......
Page 39: ...E4H Series Operation Maintenance Manual 39 1 2450 Front Panel with Display ...
Page 45: ...E4H Series Operation Maintenance Manual 45 A 6 Technician Level Menus ...
Page 46: ...E4H Series Operation Maintenance Manual 46 A 1 8 Operation ...
Page 47: ...E4H Series Operation Maintenance Manual 47 ...
Page 48: ...E4H Series Operation Maintenance Manual 48 ...
Page 49: ...E4H Series Operation Maintenance Manual 49 A 1 9 Relays ...
Page 50: ...E4H Series Operation Maintenance Manual 50 A 1 10 Alarms ...
Page 51: ...E4H Series Operation Maintenance Manual 51 A 1 11 Flow Meters ...
Page 52: ...E4H Series Operation Maintenance Manual 52 A 1 12 4 20 mA Output ...
Page 53: ...E4H Series Operation Maintenance Manual 53 A 1 13 System Setup ...
Page 54: ...E4H Series Operation Maintenance Manual 54 ...
Page 55: ...E4H Series Operation Maintenance Manual 55 ...
Page 56: ...E4H Series Operation Maintenance Manual 56 ...
Page 57: ...E4H Series Operation Maintenance Manual 57 A 1 14 Clock ...
Page 58: ...E4H Series Operation Maintenance Manual 58 A 7 Security Level Menus ...
Page 59: ...E4H Series Operation Maintenance Manual 59 A 8 Operator View Level Menus ...