1.5.6.
RO Membrane Rejection
E4H reverse osmosis machines use GE Fiberglass Reinforced Plastic (FRP) covered
AG4040F membrane elements. For ordering information refer to the attached Spare
Parts List. See Table 3 below for details.
Table 3. Membrane Element Specifications – AG4040F*
Outer Cover Material
FRP
Typical Ionic Rejection (TDS)*
99.0 – 99.5%
Nominal Permeate Flow Rate at 225 psi
2,200 gpd (8.3m
3
/day)
Typical Feed Water Temperature Range
50 – 85°F (10-29.4
°
C)
Maximum Temperature
122°F (50
°
C)
pH Range
4.0 – 11.0
Chlorine Tolerance
< 0.01 ppm
Active Membrane Area
85 ft
2
(7.9 m
2
)
*Specification is based on a 2,000 mg/L NaCl solution at 225 psi (1,551 kPa) operating pressure, 77°F
(25°C), pH 7.5 and 15% recovery. Individual flux may vary +25%/-15%. Average salt rejection after a
minimum of 24 hours of continuous operation.
2. INSTALLATION
2.1. Mounting
E4H Series machines are equipped with a stand-alone frame, which supports the
machine. At least 45 inches (114 cm) of space should be allowed on each end of the
membrane element housings for removal and loading of membrane elements. If 45
inches (114 cm) are not available, the entire membrane element housing may need to
be removed for membrane element replacement.
2.2. Piping
The E4H comes with threaded NPT fittings.
Table 4. Connection Schedule
Model
E4H-16K E4H-21K E4H-27K E4H-38K E4H-43K
Inlet
1.5-inch 1.5-inch 1.5-inch 1.5-inch 1.5-inch
Permeate
1.0-inch 1.0-inch 1.0-inch 1.0-inch 1.0-inch
Concentrate
1.0-inch 1.0-inch 1.0-inch 1.0-inch 1.0-inch
2.2.1. Inlet
Piping
The feed water source is piped to the inlet using 1.5-inch NPT fittings. A CIP system is
supplied with the DLX Model E4H.
FOR ECN MODEL:
To install a CIP system, remove plug and install valves on the E-
Series machine as described in Section 2.2.2. If the inlet pressure is in excess of 60
Summary of Contents for Osmonics E4H Series
Page 36: ......
Page 39: ...E4H Series Operation Maintenance Manual 39 1 2450 Front Panel with Display ...
Page 45: ...E4H Series Operation Maintenance Manual 45 A 6 Technician Level Menus ...
Page 46: ...E4H Series Operation Maintenance Manual 46 A 1 8 Operation ...
Page 47: ...E4H Series Operation Maintenance Manual 47 ...
Page 48: ...E4H Series Operation Maintenance Manual 48 ...
Page 49: ...E4H Series Operation Maintenance Manual 49 A 1 9 Relays ...
Page 50: ...E4H Series Operation Maintenance Manual 50 A 1 10 Alarms ...
Page 51: ...E4H Series Operation Maintenance Manual 51 A 1 11 Flow Meters ...
Page 52: ...E4H Series Operation Maintenance Manual 52 A 1 12 4 20 mA Output ...
Page 53: ...E4H Series Operation Maintenance Manual 53 A 1 13 System Setup ...
Page 54: ...E4H Series Operation Maintenance Manual 54 ...
Page 55: ...E4H Series Operation Maintenance Manual 55 ...
Page 56: ...E4H Series Operation Maintenance Manual 56 ...
Page 57: ...E4H Series Operation Maintenance Manual 57 A 1 14 Clock ...
Page 58: ...E4H Series Operation Maintenance Manual 58 A 7 Security Level Menus ...
Page 59: ...E4H Series Operation Maintenance Manual 59 A 8 Operator View Level Menus ...