NX-591E
5
V.
ENROLLING THE MODULE
The NetworX control panels have the ability to automatically find and store in memory the presence of
all keypads, zone expanders, wireless receivers, and any other device on the keypad buss. This
allows these devices to be supervised by the control panel. To enroll the devices, enter the Program
Mode of the NX control panel using the procedure outlined in the NX Installation Manual. When the
Program Mode is exited, the NX control will automatically enroll all the devices. The enrolling process
takes about 12 seconds, during which time the
A
Service
@
LED will illuminate. When using the LCD
Keypad, the "Service Required" message will be displayed. User codes will not be accepted during
the enrolling process. Once a module is enrolled, if the control panel does not detect it, the
A
Service
@
LED will illuminate.
VI.
WIRING THE MODULE
MAXIMUM WIRE RUN
LENGTH
(IN FEET)
WIRE GAUGE
(Connected To NX Control Panel or NX320E Power Supply)
10
20
50
18
100
16
VII. TERMINAL DESCRIPTION
TERMINAL
DESCRIPTION
POS
Connect to the KP POS terminal of the panel. Refer to “Specifications” in
this manual for power consumption.
COM
Connect to the KP COM terminal of the panel.
DATA
Connect to the KP DATA terminal of the panel.
TAMPER
Normally closed