NX-591E
11
XI.
PROGRAMMING INSTRUCTIONS
Location 0
Programming the Mode
5 segments Numeric Data
This location contains the System Identification Number (SID). Factory default is 0-0-0-0-0 for
AutoSID.
Location 1
Feature Selection
4 segments Feature Selection Data
Segment 1 contains the options to be programmed for the functioning of this module. Factory default
for all options is OFF.
Option Description
ON
OFF
1
Format SIA
Contact ID
2
Test Signal
Daily
Weekly
3
System Preference
Use “A” or “B” side only
No Preference
4
“B” Side Preference
“B” Side (if Opt 3 is ON)
“A” Side
5
Alternate MIN
Disabled
Enabled
6
Disable Cellular Service LEDs
Disabled
Enabled
7
Enable Tamper Switch
Enabled
Disabled
8
Disable SIA DCS Area
Modifier
Disabled
Enabled
Segment 2 programs for
Host Acknowledgement
requirements. Factory default for all options is
OFF.
Option Description
ON
OFF
1
Central Station messages
Enabled
Disabled
2
Email messages
Enabled
Disabled
3
Pager messages
Enabled
Disabled
4
Periodic test signals
Enabled
Disabled
5-8
Reserved
Segments 3 and 4 are reserved for future use.
Notes:
Daily test will be performed 24 hours (+/- 10 minutes) from time this option is programmed.
Weekly test will be performed 168 hours (+/- 10 minutes) from time this option is programmed.
Some older SIA DCS compatible receivers may not support the use of area (partition) modifiers.
In such cases, the area modifier must be disabled (Option 8 ON).