NX-591E
4
3.
Several options are available on the left side of the next screen.
a.
“
Activate Unit
” -- This will activate the cellemetry unit. Enter the serial number of the
cellemetry module (located on the front of the unit).
Note: The serial number must contain
10 digits.
Verify that the Service Plan Description indicates, “Security Plan”. Click
“Activate”. Multiple units can be added from this screen.
b.
“
Edit Unit Settings
” -- Complete the information based on the way you want
to configure the reporting for the unit.
o
Select the unit you have just activated
o
Add the Account Name to the Unit Name field
o
Select your Notification Method 1
o
Change TX Retries to 8 (maximum allowed)
o
Go to the appropriate field for the Method 1 that was chosen (Alpha, Email or Central Station)
If Alpha Pager, the PIN number is required
If Central Station, enter the Receiver Phone Number & Central Station A/C
number
o
Select a 2
nd
Notification Type, if needed.
o
Notification Enabled should read “Yes”.
o
Click “Update” (bottom of page)
III.
ENCLOSURE INFORMATION
Inside the can, several 2-holed insertion points have been constructed.
This allows for either vertical or horizontal placement of the modules.
Notice that the insertion points have two sizes of holes -- a larger
hole and a smaller hole
.
Diagram 1
: The black plastic PCB guides are grooved on one edge where
the PC Board will be seated. The end with the half-moon protrusion fits
into the larger hole. The smaller hole is for the screw.
Diagram 2
: Place the
first
black plastic PCB guide in the top insertion
point, grooved edge downward. The half-moon protrusion will be in the
large hole. It does not require force. Insert one of the provided screws into
the smaller hole (from inside the can) to secure it in place. A screwdriver
should reach through the notch that runs the length of the guide to tighten
the screw. The
second
PCB guide should be positioned opposite of the
first (grooved edge up) and placed in the lower insertion point, using the
same procedures described above. Once mounted, screw it in securely.
Diagram 3
: The PC board should slide freely in the grooves of both
guides.
NOTE: Older style enclosures did not provide an exit hole for the 2dB “Rubber Duck” antenna
included with the Cellemetry module. In such cases, you must either drill a new hole on top of the can
or use an optional external antenna such as the 5dB “Mag Mount”.
IV.
MODULE ADDRESS
The cellemetry module has a fixed address of
76
. When programming the module, enter the Program
Mode and select the device address as 76. (See "PROGRAMMING THE MODULE", page 8.)