NX-1710E Single Door Control
9
VII.
USER CARDS
Adding and de-activating users is done through a combination of entering information at the keypad and
scanning cards. Before a card can be entered, one door control on the system must be programmed with User
Card Programming enabled (Location 3, Segment 1, Option 1, page 14).
It is recommended that only one door control on the system be enabled to modify user
cards and that this reader be located near a keypad. This reader will transfer information to
all other readers in the system once programming is finished.
Once a door control is enabled to modify users, it must be placed into one of the following five modes:
1)
Add One User
2)
Add Multiple Users w/ Auto-Increment
3)
Activate One User
4)
De-Activate One User
5)
Delete/Reset One User.
Modifying users on a door control is similar to modifying user codes at a keypad.
E
NTER
U
SER
P
ROGRAMMING
Accesses Code Programming
[
master code
]
Factory Default is
If the code is valid, the Ready LED will flash.
User Number 2 is used to program user
cards, so…
if control is an NX-4, NX-6,
or NX-8
if control is an NX-8E
Unit is now ready for you to choose one of the
User Card Programming modes (as if user
code 2):
$
Add One User
$
Add Multiple Users (w/Auto-Increment)
$
Activate Single User
$
De-activate One User
$
Delete / Reset One User
IMPORTANT NOTES
1. Adding or de-activating user cards from a door control will cause the code for User Number 2 to become
invalid. Therefore, it will need to be re-entered after all user cards are programmed into the door control.
2. By default, user cards are added and activated.
A
DDING
O
NE
U
SER
[
STAY
]
Accesses Activation mode
[
3-digit user number
]
Example:
if 4-digit user
code or
if 6-digit
If a valid user number is entered, LED1
(Green) on any enabled readers will begin to
flash.
Scan the card designated for the user
entered in the previous step.
If the user card is not already in the system, it
will be added and mapped to the entered user
number and LED1 (Green) will flash.
If the card is already in the system, the reader
will triple beep and LED1 (Green) will continue
flashing; the user number is not incremented in
this case.
Must be a
master user in
order to modify
user card
information.