NX-1710E Single Door Control
14
L
OCATION
3 P
ROGRAMMING THE
O
PTIONS AND
D
OOR
C
ONTROL
P
ARTITIONS
(4 segments of binary data)
Segment 1
Unit Options:
LED1 -
"On" if door control module is enabled for User Card Programming.
LED2 -
"On" if tamper is enabled.
LED3 -
"On" if disabling on-board zone.
LED4 -
Reserved.
LED5 -
“On” if an RTE from a scanned card is to be logged as Code Entry.
LED6 -
“On” if an RTE from a zone or the egress input is logged as Code Entry.
LED7–8
Reserved.
Segment 2
Door Options
LED1 -
"On" if locking mechanism is a Maglock or Drop Bolt.
LED2 -
"On" if access is allowed regardless of Armed status of the system.
LED3 -
"On" if the door is not to be latched unlocked during an open schedule.
LED4 -
"On" if onboard relay only triggers during an open schedule.
LED5 -
“On” if onboard relay only triggers during a close schedule.
LED6 -
“On” if Forced Entry Alarm is logged.
LED7 -
“On” if access allowed without an RTE.
LED8 -
“On” if relay operates normally during off-schedule
(outside regular operating hours).
Segment 3
Enabling the Schedules for the Onboard Relay:
LED1 -
"On" if driver follows Schedule 1. (Default is “On”)
LED2 -
"On" if driver follows Schedule 2. (Default is “On”)
LED3 -
"On" if driver follows Schedule 3. (Default is “On”)
LED4 -
"On" if driver follows Schedule 4. (Default is “On”)
LED5 -
"On" if driver follows Schedule 5. (Default is “On”)
LED6 -
"On" if driver follows Schedule 6. (Default is “On”)
LED7 -
"On" if driver follows Schedule 7. (Default is “On”)
LED8 -
"On" if driver follows Schedule 8. (Default is “On”)
Segment 4
Door Control Partition:
LED1 -
"On" if door control is in Partition 1. (Default is “On”)
LED2 -
"On" if door control is in Partition 2. (Default is “On”)
LED3 -
"On" if door control is in Partition 3. (Default is “On”)
LED4 -
"On" if door control is in Partition 4. (Default is “On”)
LED5 -
"On" if door control is in Partition 5. (Default is “On”)
LED6 -
"On" if door control is in Partition 6. (Default is “On”)
LED7 -
"On" if door control is in Partition 7. (Default is “On”)
LED8 -
"On" if door control is in Partition 8. (Default is “On”)
Segment 5
Weigand Format Enables:
LED1 -
"On" if Weigand Format #1 is enabled. (Default is “On”)
LED2 -
"On" if Weigand Format #2 is enabled. (Default is “On”)
LED3 -
"On" if Weigand Format #3 is enabled. (Default is “On”)
LED4 -
"On" if Weigand Format #4 is enabled. (Default is “On”)
LED5 -
"On" if Weigand Format #5 is enabled. (Default is “On”)
LED6 -
"On" if Weigand Format #6 is enabled.
LED7 -
"On" if Weigand Format #7 is enabled.
LED8 -
"On" if Weigand Format #8 is enabled.