NX-1710E Single Door Control
32
LOCATION 112 – WIEGAND FORMAT 6 (BIT DESCRIPTOR 33 - 64)
0 = Always Zero; 1 = Always One; B = Badge Number Bit; D = Parity Bit; E = End of Format; F = Facility Code Bit
SEG
DESCRIPTION DEFAULT
DATA SEG
DESCRIPTION DEFAULT
DATA
1
Bit 33 Descriptor
B
17
Bit 49 Descriptor
E
2
Bit 34 Descriptor
B
18
Bit 50 Descriptor
E
3
Bit 35 Descriptor
B
19
Bit 51 Descriptor
E
4
Bit 36 Descriptor
B
20
Bit 52 Descriptor
E
5
Bit 37 Descriptor
B
21
Bit 53 Descriptor
E
6
Bit 38 Descriptor
B
22
Bit 54 Descriptor
E
7
Bit 39 Descriptor
B
23
Bit 55 Descriptor
E
8
Bit 40 Descriptor
D
24
Bit 56 Descriptor
E
9
Bit 41 Descriptor
E
25
Bit 57 Descriptor
E
10
Bit 42 Descriptor
E
26
Bit 58 Descriptor
E
11
Bit 43 Descriptor
E
27
Bit 59 Descriptor
E
12
Bit 44 Descriptor
E
28
Bit 60 Descriptor
E
13
Bit 45 Descriptor
E
29
Bit 61 Descriptor
E
14
Bit 46 Descriptor
E
30
Bit 62 Descriptor
E
15
Bit 47 Descriptor
E
31
Bit 63 Descriptor
E
16
Bit 48 Descriptor
E
32
Bit 64 Descriptor
E
LOCATION 113 – WIEGAND FORMAT 6(PARITY TYPE 1)
0=No Parity; 1=Odd Parity; 2=Even Parity
1
Parity Type 1
1
LOCATION 114 – WIEGAND FORMAT 6 (PARITY MASK 1)
1
Parity Mask 1
12345678
5
Parity Mask 5
12345678
2
Parity Mask 2
12345678
6
Parity Mask 6
--------
3
Parity Mask 3
12345678
7
Parity Mask 7
--------
4
Parity Mask 4
12345678
8
Parity Mask 8
--------
LOCATION 115 – WIEGAND FORMAT 6 (PARITY TYPE 2)
0=No Parity; 1=Odd Parity; 2=Even Parity
1
Parity Type 2
2
LOCATION 116 – WIEGAND FORMAT 6 (PARITY MASK 2)
1
Parity Mask 1
12345678
5
Parity Mask 5
--------
2
Parity Mask 2
12345678
6
Parity Mask 6
--------
3
Parity Mask 3
----5678
7
Parity Mask 7
--------
4
Parity Mask 4
--------
8
Parity Mask 8
--------
LOCATION 117 – WIEGAND FORMAT 6 (PARITY TYPE 3)
0=No Parity; 1=Odd Parity; 2=Even Parity
1
Parity Type 3
0
LOCATION 118 – WIEGAND FORMAT 6 (PARITY MASK 3)
1
Parity Mask 1
--------
5
Parity Mask 5
--------
2
Parity Mask 2
--------
6
Parity Mask 6
--------
3
Parity Mask 3
--------
7
Parity Mask 7
--------
4
Parity Mask 4
--------
8
Parity Mask 8
--------
LOCATION 119 – WIEGAND FORMAT 6 (PARITY TYPE 4)
1
Parity Type 4
0
LOCATION 120 – WIEGAND FORMAT 6 (PARITY MASK 4)
1
Parity Mask 1
--------
5
Parity Mask 5
--------
2
Parity Mask 2
--------
6
Parity Mask 6
--------
3
Parity Mask 3
--------
7
Parity Mask 7
--------
4
Parity Mask 4
--------
8
Parity Mask 8
--------
LOCATION 121 – WIEGAND FORMAT 6 (PARITY TYPE 5)
1
Parity Type 5
0
LOCATION 122 – WIEGAND FORMAT 6 (PARITY MASK 5)
1
Parity Mask 1
--------
5
Parity Mask 5
--------
2
Parity Mask 2
--------
6
Parity Mask 6
--------
3
Parity Mask 3
--------
7
Parity Mask 7
--------
4
Parity Mask 4
--------
8
Parity Mask 8
--------
WEIGAND FORMAT 7
LOCATION 123 – WIEGAND FORMAT 7 (DIGITS & BITS) (DECIMAL DATA)
DESCRIPTION
DEFAULT
DATA
1
Number of Digits in Facility Code
0
2
Number of Digits in Badge Number
0
3
Number of Bits in Facility Code
0
4
Number of Bits in Badge Number
0
5
Total Number of Bits in Complete Weigand
Format (including parity bits)
0