background image

 

       

 

 

NX-7002 

LAYOUT AND DESCRIPTION

 

 

 

 

  1 

     1 

 

11 

 

 

10 

 7 

   5 

 7 

 

 

DESCRIPTION 

Future use (VVMIQ) 

SIM card holder 

GPRS modem 

Connect antenna to this connector 

Header for software upgrade 

Connect to battery  

Connect main panel battery leads to these connectors 

Audio tap connector (CON5) 

If the NX-7002 uses the voice channel for event reporting, the special audio cable 

(included) needs to be stuffed between this connector of the NX-7002 and the Audio 

Tap connector of the control panel. 

Keypad bus terminals 

10 

Status LED’s 

GSM in use

: ON when events are send over the voice or data channel (Up/download) 

PSU error

: ON when the modem power source is to low 

Reporting

: ON when data is reported to the IP receiver or Mobile phone (SMS) 

GPRS active

: ON when the module is connected to the GPRS network and the first event is 

send. It turns OFF when the module uses the voice channel 

SIM error

: ON when an incorrect PIN code is entered 

GSM com

: reserved 

Network OK

: reserved 

Bus com

: flashes when communicating on the NetworX bus 

11 

Green LED

: ON when connected to TCP/IP receiver 

 

 

NX-7002 Installation manual 

Page 33

 

 

09/02/05 

Summary of Contents for NetworX NX-7002

Page 1: ...GE Security NetworX TM Series NX 7002 GSM GPRS module Installation manual g imagination at work ...

Page 2: ...NX 7002 Installation manual Page 2 09 02 05 ...

Page 3: ...NX 7002 10 INSERTING THE SIM CARD 10 ENROLLING THE SIM CARD ON THE GSM NETWORK 11 ENROLLING THE SIM CARD ON THE GPRS NETWORK 11 TESTING THE RSSI VALUE 12 TESTING THE GSM AND GPRS CONNECTION 12 PROGRAMMING THE LOCATIONS 13 NX 7002 FOR PRIMARY OR BACKUP REPORTING 24 NX 7002 FOR PRIMARY REPORTING 24 NX 7002 FOR BACKUP REPORTING 24 NX 7002 PROGRAMMING WORKSHEETS 26 INSTALLATION GUIDELINES 32 MOUNTING ...

Page 4: ...g GSM Wireless upload download using a GSM CSD connection Upload download may be initiated remotely or locally Optional download sessions during test calls The NX 7002 package contains NX 7002 GSM GPRS module 1 5m external antenna 2 black PCB guides for mounting Audio cable The GSM GPRS module requires a SIM card not included In order to obtain all NX 7002 features the SIM card needs to support Vo...

Page 5: ...n with TCP IP reporting only Polling is more frequent than a daily test call but less frequent than continuous monitoring If you configure a very short polling time polling occurs very frequently and can generate large quantities of data When setting the polling time you should consider the speed of the GPRS network and the cost of data transmission see location 0 segment 3 and location 162 segmen...

Page 6: ...ervice SMS is a service for sending short text messages to mobile phones see locations 1 145 163 164 167 Transparent mode Data is transferred directly from one modem to another modem see location 0 segment 1 NX 7002 Installation manual Page 6 09 02 05 ...

Page 7: ...ady LED will illuminate and the zone LED s will show the binary data for the first segment of this location While entering new data the Ready LED will begin flashing to indicate a data change in process The flashing will continue until the new data is stored by pressing the key Upon pressing the key the keypad will advance to the next segment and display its data This procedure is repeated until t...

Page 8: ...on you were previously changing For example if the display reads Enter location then 5 it is reminding you that location 5 was the last location you programmed Refer also to Programming Data which follows Programming data Programming data is always one of two types One type of data is numerical which can have values from 0 15 or 0 255 depending on the segment size The other type of data feature se...

Page 9: ...that corresponds to the feature number within a segment will toggle on off that feature Pressing any numeric key between 1 and 8 for selection of a feature will make the corresponding LED illuminate feature ON Press the number again and the LED will extinguish feature OFF You will see that numerous features can be selected from within one segment For instance if all eight features of a segment are...

Page 10: ...y in the holder and close the SIM card holder r Slide the metal clip back to the original position as shown in s Power up the system Do not enter programming mode until the SIM card selects the network operator The SIM card automatically selects a network operator when enrolled on the network To manually select an operator enter the relevant network operator in location 170 See Appendix 2 Operator...

Page 11: ...rk Enter programming mode Press 78 to select the module Press 169 to enter the GSM SIM PIN code location Enter the first digit of the SIM PIN code Press to move to the next segment Continue in this way until all digits are programmed Press to save the changes and exit the location Obtain an Access Point Number from the supplier Press 60 to enter the Name of GPRS access point APN location Enter the...

Page 12: ...ther location Between 10 and 16 These are normal working values for the module located at a longer distance from the receiver Above 17 Perfect conditions Enter programming mode Press 78 to select the NX 7002 GPRS module Press 172 to select the Current GPRS RSSI location Note the RSSI reading and quit programming Testing the GSM and GPRS connection Enter programming mode Press 78 to select the NX 7...

Page 13: ...to accept an incoming call 99 as soon as a ding dong is heard on the keypad 6 Callback required for incoming CSD GSM download call If enabled the NX 7002 will call back to the PC before starting an up download session 7 Use V 110 for site initiated CSD GSM calls Enable this setting if the PC is on an ISDN line and is using an ISDN modem 8 Use non transparent mode for site initiated CSD GSM calls I...

Page 14: ...format SIA or CID in location 0 segment 2 option 1 and enable test report events for the backup device This location contains the backup report destination for report control 1 Select from the table below DATA FORMAT DESCRIPTION 0 Disabled Backup Report control 1 is disabled 1 TCP IP 1 Backup Reporting to TCP IP receiver 1 2 TCP IP 2 Backup Reporting to TCP IP receiver 2 3 Email 1 Backup Email Rep...

Page 15: ...LECTION FOR REPORT CONTROL 2 1 segment This location contains the report destination for report control 2 See location 1 LOCATION 6 BACKUP DESTINATION SELECTION FOR REPORT CONTROL 2 1 segment This location contains the backup report destination for report control 2 See location 2 LOCATION 7 REPORT DELAY FOR REPORT CONTROL 2 1 segment The delay in seconds before the NX 7002 GPRS module reports to r...

Page 16: ...is location contains the report destination for report control 5 See location 1 LOCATION 18 BACKUP DESTINATION SELECTION FOR REPORT CONTROL 5 1 segment This location contains the backup report destination for report control 5 See location 2 LOCATION 19 REPORT DELAY FOR REPORT CONTROL 5 1 segment The delay in seconds before the NX 7002 GPRS module reports to report control 5 See location 3 LOCATION...

Page 17: ... 4 acts as Primary Reporting Off Report Control 4 acts as Secondary Reporting 5 On Report Control 5 acts as Primary Reporting Off Report Control 5 acts as Secondary Reporting 6 On Report Control 6 acts as Primary Reporting Off Report Control 6 acts as Secondary Reporting 7 8 Reserved LOCATION 26 LOCATION 31 RESERVED LOCATION 32 PPP dial up account USER ID characters 1 16 16 segments Optional if us...

Page 18: ... AND POLL PORT 4 segments The number of the TCP IP port to which polling and alarms are reported The default port is 9999 and under normal circumstances should not be changed LOCATION 120 LOCATION 138 RESERVED LOCATION 139 TCP IP 1 ACCOUNT NUMBER 8 segments The SIA or Contact ID account number used for reporting towards the TCP IP receiver SIA account numbers are 6 digits long Contact ID account n...

Page 19: ...ported Use when a different account code for each partition is required When there is also an account code set for each report destination see location 139 142 145 146 the partition account code takes precedence LOCATION 155 ACCOUNT NUMBER FOR PARTITION 2 8 segments See location 154 LOCATION 156 ACCOUNT NUMBER FOR PARTITION 3 8 segments See location 154 LOCATION 157 ACCOUNT NUMBER FOR PARTITION 4 ...

Page 20: ...ment 8 Reserved Segment 9 Reserved Segment 10 Baud rate for CSD GSM download This setting must match the baud rate set on the PC modem 4 2400 Baud 5 4800 Baud 6 9600 Baud Segment 11 GSM line fault RSSI threshold The acceptable level of the RSSI signal If the signal falls below this level for the amount of time set in segment 12 a line fault is generated This can be from 1 to 31 If set to 0 the set...

Page 21: ...6 BA001 If 1 Combined Events is selected messages are sent using the syntax aaaaaa eennn eennn aaaaaa eennn eennn For example 123456 BA001 987654 YT000 345678 TA030 If 2 Area Modifier is selected messages are sent using the syntax aaaaaa eennn Rin eennn Rin For example 987654 BA001 Ri1 BA003 Ri1 YT000 TA030 Ri3 Syntax Description The message opening character aaaaaa A six digit account code ee A t...

Page 22: ...in code in this location A 10 indicates the end of the code LOCATION 170 GSM OPERATOR SELECTION 6 segments The network operator ID code Set this to 00000 to allow the SIM card automatically select a network operator Alternatively enter an operator ID code in this location to manually select a network operator If using a 5 digit code enter A or 10 after the code Appendix 2 lists all network operato...

Page 23: ...failure The bus supplies a 13 8 V voltage to the NX 7002 4 On Communication channel failure 5 On Up download session in progress 6 On Up download session starting 7 On Reporting in Progress 8 On RSSI level at acceptable level LOCATION 175 GSM MODEM MANUFACTURER READ ONLY 16 segments This location displays the manufacturer of the GSM GPRS modem used on the NX 7002 LOCATION 176 GSM MODEM MODEL READ ...

Page 24: ...SMS1 NX 7002 for backup reporting The NX 7002 can be configured to transmit events only when the primary dialler control panel auxiliary dialler fails to do so In this case the NX 7002 acts as the backup reporting device The NX 7002 can be configured as the backup device of the control panel in two ways 1 Backup reporting using a report control TCP IP or SMS Select the desired report control in lo...

Page 25: ...TCP IP module or NX 570 ISDN module Select the desired report control in location 1 Enable the Autotest report options Ensure that the reporting format used with the auxiliary dialler is the same as the reporting format used in the NX 7002 NX 7002 Installation manual Page 25 09 02 05 ...

Page 26: ...served 6 Reserved 7 Reserved 7 Reserved 0 13 8 Reserved 8 Reserved 1 14 DESTINATION SELECTION FOR REPORT CONTROL 1 0 2 14 BACKUP DESTINATION SELECTION FOR REPORT CONTROL 1 0 3 14 REPORT DELAY FOR REPORT CONTROL 1 0 EVENT SELECTION FOR REPORT CONTROL 1 BY PARTITION Segment 1 Alarms and Restores 1 2 3 4 5 6 7 8 Segment 2 Open Close 1 2 3 4 5 6 7 8 Segment 3 Bypass 1 2 3 4 5 6 7 8 Segment 4 Zone Trou...

Page 27: ...10 16 BACKUP DESTINATION SELECTION FOR REPORT CONTROL 3 0 11 16 REPORT DELAY FOR REPORT CONTROL 3 0 EVENT SELECTION FOR REPORT CONTROL 3 BY PARTITION Segment 1 Alarms and Restores 0 0 0 0 0 0 0 0 Segment 2 Open Close 0 0 0 0 0 0 0 0 Segment 3 Bypass 0 0 0 0 0 0 0 0 Segment 4 Zone Trouble 0 0 0 0 0 0 0 0 Segment 5 Power Trouble AC Failure Low Batt 0 0 0 0 0 0 0 0 Segment 6 Siren Telephone Fault 0 0...

Page 28: ... 18 16 BACKUP DESTINATION SELECTION FOR REPORT CONTROL 5 0 19 16 REPORT DELAY FOR REPORT CONTROL 5 0 EVENT SELECTION FOR REPORT CONTROL 5 BY PARTITION Segment 1 Alarms and Restores 0 0 0 0 0 0 0 0 Segment 2 Open Close 0 0 0 0 0 0 0 0 Segment 3 Bypass 0 0 0 0 0 0 0 0 Segment 4 Zone Trouble 0 0 0 0 0 0 0 0 Segment 5 Power Trouble AC Failure Low Batt 0 0 0 0 0 0 0 0 Segment 6 Siren Telephone Fault 0 ...

Page 29: ...ort Control 3 is Backup for control panel 4 On Report Control 4 is Primary Reporting Flag Off Report Control 4 is Backup for control panel 5 On Report Control 5 is Primary Reporting Flag Off Report Control 5 is Backup for control panel 6 On Report Control 6 is Primary Reporting Flag Off Report Control 6 is Backup for control panel 7 Reserved 25 17 8 Reserved 26 31 17 RESERVED 32 18 PPP dial up acc...

Page 30: ...nt 9 Reserved Segment 10 Baud rate for CSD GSM download 6 Segment 11 GSM line fault RSSI threshold 5 Segment 12 GSM line fault time in seconds 20 Segment 13 Control reporting timeout in seconds for secondary reporting 180 Segment 14 Reserved Segment 15 Reserved 162 21 Segment 16 Reserved 22 SMS 1 Phone number 14 14 14 14 14 14 14 14 14 14 14 14 14 14 14 14 14 14 14 14 164 22 SMS 1 Format 0 165 22 ...

Page 31: ...ilure 2 On GSM PSU voltage failure 3 On Bus voltage failure 4 On Communication channel failure 5 On U D session in progress 6 On U D session starting 7 On Reporting in progress 8 On Good RSSI Level Segment 3 1 On Max reports in 24h limit reached 174 24 2 8 Reserved 175 24 GSM modem manufacturer read only name of manufacturer 176 24 GSM modem model read only name of model 177 24 GSM modem software ...

Page 32: ...ed This allows for either vertical or horizontal placement of the modules Notice that each insertion point has two sizes of holes a larger hole and a smaller hole Diagram 1 The black plastic PCB guides are grooved on one edge where the PC board will be seated The end with the half moon protrusion fits into the larger hole The smaller hole is for the screw Diagram 2 Place the first black plastic PC...

Page 33: ...Tap connector of the control panel 9 Keypad bus terminals 10 Status LED s GSM in use ON when events are send over the voice or data channel Up download PSU error ON when the modem power source is to low Reporting ON when data is reported to the IP receiver or Mobile phone SMS GPRS active ON when the module is connected to the GPRS network and the first event is send It turns OFF when the module us...

Page 34: ...12Vdc Current consumption Nominal 30mA at 13 8Vdc Maximum up to 2 Amps peak Battery max 12V 7 2Ah Operating temperature 0 49 C Humidity Max 93 non condensating Dimensions PCB board only WxHxD 102 x 97 x 24 mm Weight PCB board only 115 g NX 7002 Installation manual Page 34 09 02 05 ...

Page 35: ...OWER OVERCURRENT device number 312 YP AUX POWER RESTORE device number 312 YQ LOW BATTERY device number 309 YT LOW BATTERY RESTORE device number 309 YR AC FAIL device number 301 AT AC RESTORE device number 301 AR BOX TAMPER device number 137 TA BOX TAMPER RESTORE device number 137 TR KEYPAD TAMPER 137 TA KEYPAD PANIC audible 120 PA KEYPAD PANIC silent 121 HA DURESS 121 HA KEYPAD AUXILIARY 1 110 FA ...

Page 36: ...ARENTHESES FOLLOWING THE EVENT IS THE NUMBER THAT WILL BE REPORTED AS THE ZONE NUMBER IF THERE ARE NO PARENTHESES THE ZONE WILL BE 0 The character transmitted in this slot will be the first character from the event code of the zone that is bypassed or in trouble SPECIAL REPORTS CONTACT ID SIA FAIL TO COMMUNICATE TCP IP or SMS 354 RT002 GSM network failure RSSI value to low 354 RT078 NX 7002 Instal...

Page 37: ...municazioni SpA 22288 I WIND H3G H3G 22299 3ITA Ireland Vodafone Ireland Plc Vodafone 27201 IRL Voda Eircell Eir Gsm O2 Communications Ireland Ltd O2 Communications Ireland Ltd 27202 O2 IRL METEOR METEOR 27203 METEOR Jersey Guernsey and Isle of Man Jersey Telecom JT GSM 23450 JT GSM Cable Wireless Guernsey Ltd Cable Wireless Guernsey 23455 C W Manx Telecom Pronto GSM 23458 Pronto Netherlands Vodaf...

Page 38: ... HI3G Access AB 3 24002 3 Tele 2 AB COMVIQ 24007 IQ Vodafone Sverige AB Vodafone 24008 voda SE Swefour AB Swefour AB 24010 Spring United Kingdom O2 UK Limited O2 23410 O2 UK Vodafone Ltd Vodafone 23415 Voda Hutchison 3G UK Ltd 3 23420 3 UK T Mobile UK Limited T Mobile UK 23430 TMO UK T Mobile UK Limited T Mobile UK 23431 TMO UK T Mobile UK Limited T Mobile UK 23432 TMO UK Orange PCS Ltd Orange 234...

Page 39: ...A bvba COPYRIGHT 2005 GE Security EMEA bvba All rights reserved GE Security EMEA bvba grants the right to reprint this manual for internal use only GE Security EMEA bvba reserves the right to change information without notice NX 7002 Installation manual Page 39 09 02 05 ...