Attach the Cellar Management
System Module to the Wine Vault

Step 1:

Center the template between the left
edge of the wine vault and the digital
temperature display. Align the bottom
edge just above the electrical power
cord cover plate. Use a spirit level to
check horizontal position. Tape template
into place.

Step 2:

Use a center punch to mark the 8 screw
locations. Remove the template. 

Step 3:

Open the printer cover and install a
mounting screw in the upper left corner
of the mounting plate.

Step 4

Drill 1/8” pilot holes at the marked
locations.

Step 5:

Fold the CPU away from the mounting
bracket. Do not separate the two pieces.

Step 6:

Secure the mounting bracket to the wine
vault with at least eight screws.

Step 7:

Insert the protruding screw heads on the
mounting bracket into the keyhole slots
on the console. Slide the console
downward to lock into place.

Step 8: 

Unlock the CPU and swing the front
panel fully open. Tighten the 4 corner
mounting screws. Close and lock the
front panel.

Step 9:

Connect the power cord to the console.

DO NOT CONNECT THE WINE VAULT POWER
CORD AT THIS TIME.

INSTALL THE CELLAR MANAGEMENT SYSTEM

The Cellar Management System module consists of an LCD touch screen with an
integrated label printer and barcode scanner. The System features easy-to-use 
software and includes a pre-installed database of thousands of wines.

LOCATE THE FINAL INSTALLATION CHECKLIST (Pub. No. 49-60383) IN

THE LITERATURE PACKAGE. THE FORM MUST BE FILLED OUT

COMPLETELY AND SIGNED BY THE HOME OWNER.

INSTALLATION INSTRUCTIONS

Tighten corner mounting screws

Fit screw
heads into
keyhole slots

Summary of Contents for Monogram ZWVS1000SR

Page 1: ...7 61 4 8 81 2 7 9 Internet access port Monogram Wine Vault Installation Instructions...

Page 2: ...Due to the size and weight of the panels and cooling unit at least four people are required to complete this installation WARNING Do not install the Monogram Wine Vault outdoors WARNING Do not allow...

Page 3: ...onsibility and obligation to have it replaced with a properly grounded 3 prong twist lock wall outlet DO NOT USE A GFI Ground Fault Interrupter DO NOT USE AN EXTENSION CORD WITH THIS APPLIANCE DO NOT...

Page 4: ...ity Allow one day for assembly of the vault and one day to install the wine racks At least four people are required to assemble the wine vault Refer to the Pre Installation Checklist to be sure that a...

Page 5: ...h the installer may be necessary Always check that the threshold or flooring transition does not interfere with the door sweep Assembly Planning Four people are required to assemble the wine vault Pla...

Page 6: ...ll be accessible and inconspicuous KEY Approx power cord location Approx receptacle location HIGH CEILING Ceiling height is 8 ft or over The receptacle must be installed in an accessible location appr...

Page 7: ...tons to cover access holes One tube of gray silicone caulking Adhesive for wood or concrete 14 lag bolts to fasten the base channels to flooring 1 4 x 6 Hardware package which includes anchors washers...

Page 8: ...cate the three ceiling panels Lay the panels on the floor top surface up Align the outside edges of the panels and pull the panels tightly together Mark a line on the floor that is 1 2 outside the cei...

Page 9: ...lly measure the door opening Adjust the opening spacer on the template Step 3 Apply 2 beads of adhesive supplied with the wine vault in the groove on the bottom of the each base channel and press into...

Page 10: ...t panels to be sure all locking latches are fully retracted before setting them into the base channels Insert the hex key into the access hole and turn clockwise until the latch is fully retracted and...

Page 11: ...the panels should align with the base channel Note the location of the locking access holes There are two latches on the right side of each panel to secure adjacent panels together and two on the bott...

Page 12: ...e panel 46 wide panel 341 2 wide panel Step 7 Set the other 23 wide panel into the channel into the channel Lock the side panel to the corner panel Place the rear 35 ceiling panel over the top of the...

Page 13: ...ve the door opening spacer template Cut notches to permit the door jamb brackets to be installed flush on each side of the door opening Slide the brackets into the channel recesses until they are flus...

Page 14: ...eople outside lift the door panel section into place Secure the panels with the locking connectors IMPORTANT The door panel is very heavy Four people should carry and install this door panel Make sure...

Page 15: ...eposition the door panel and the corner panel Test again Step 2 Open the door Measure and mark both sides of the door jamb 3 to 3 1 4 above the floor and 2 from the front of the jamb Step 3 Drill 5 32...

Page 16: ...on enough to allow the box to fit flush into the ceiling panel Step 3 Drill a 7 8 dia hole in a blank junction box cover plate Install a strain relief Remove approximately 6 of the outer jacket of the...

Page 17: ...the top of the panel Withdraw the tubing NOTE The plastic tubing will help guide the leads through the grommet without damaging the terminals Step 3 Push the lamp housing into the recess and secure wi...

Page 18: ...the mounting screw and tighten snugly Repeat for the other two screws Step 3 Connect the light connectors to the wiring harness making sure the click into place Install the lens cover Step 4 Repeat s...

Page 19: ...with the FRONT ceiling panel Step 4 Align the center and rear panels with the front panel and outside walls and lock into place Step 5 Inspect all joints between panels and make any needed adjustments...

Page 20: ...flooring The door must close securely Check all locking connectors for tightness one at a time Press a plug button cover into each opening and tap with a rubber mallet as you proceed Connect and Test...

Page 21: ...cooling unit from the shipping carton and place it in on sturdy level work surface It is recommended that a piece of cardboard be placed underneath the cooling unit to prevent damage to the finish Ste...

Page 22: ...all the Unit in the Wine Vault WARNING The cooling unit is heavy Two people are required for installation Step 1 From the outside slide the unit into the opening in the right front wall CAUTION The op...

Page 23: ...perate the cooling unit until the location is cleared of debris Connect the Thermostat Step 1 Plug the thermostat cable into the socket on the main unit Step 2 Attach the thermostat to the mounting br...

Page 24: ...WER SWITCH CONDENSATE EVAPORATOR SWITCH The ON position of the Condensate Evaporator Switch activates the heating element whenever water is present in the evaporator pan The AUTO position of the Conde...

Page 25: ...uid temperature 2 Wine Temperature Reading The temperature of the water in the bottle as detected by the probe 3 Temperature SET Indicator A red LED lamp beside SET will light up while you are adjusti...

Page 26: ...nd has been installed by our wine rack professionals See the Owner s Manual for additional information Rope Lights on some models The rope lights are pre installed by our wine rack professionals See t...

Page 27: ...3 4 full with room temperature tap water Step 2 Place the bottle probe securely into the bottle Step 3 Place the bottle with probe in a central location out of the direct path of the air coming from t...

Page 28: ...st eight screws Step 7 Insert the protruding screw heads on the mounting bracket into the keyhole slots on the console Slide the console downward to lock into place Step 8 Unlock the CPU and swing the...

Page 29: ...m latch recesses 5 16 wrench not Insert the wrench fully before turning fully engaged DOOR FIT Door closure mechanism not working properly Possible Cause Recommended Solution Piston is missing Call 1...

Page 30: ...it the cooling unit on the inside or outside of the wine vault Faulty thermostat Plug in the by pass plug to temporarily provide cooling The unit should be replaced To remove the cooling unit reverse...

Page 31: ...oor seal Check the door seal for gaps Cooling unit is not installed Check the installation of the unit Make sure insulation properly tape is installed properly Insufficient ventilation Temperature of...