June 2003
2-22
Troubleshooting and Maintenance
* The MH and FH values are the moisture sensors response values and are the values that are recorded
during calibration.
** The FP value is the Moisture Image Series Probes response value for pressure and is the value
recorded during calibration.
Table 2-6: Measurement Modes and Units for the Series 1
Selected
Measurement
Mode
Description of Units
Displayed
Measurement
Mode
Displayed Units
Oxygen
O
2
%= Percent Oxygen
default
O
2
/ppM = Parts Per Million
O
2
/ppB = Parts Per Billion
O
2
/
µ
A = Microamps (Diagnostic Mode)
O
2
/DVM = Digital Voltmeter (Diagnostic Mode)
Oxygen
Oxygen
Oxygen
Oxygen
Oxygen DVM
%
ppm
v
ppb
v
µA
VDC
Hygrometry
DP/°C = Dew/Frost Point
default
DP/°F = Dew/Frost Point °F
DP/K = Dew/Frost Point K (Kelvin)
%R.H. = Relative Humidity
H/ppMv = Parts per Million of Water by Volume
H/ppMw = Parts per Million of Water by Weight (for
liquids only)
H/ppBv = Parts per Billion of Water by Volume
MCF/IG = Pounds of Water per Million Standard
Cubic Feet in Ideal Gas
MCF/NG = Pounds of Water per Million
Standard Cubic Feet in Natural Gas
ppMv/NG = Parts Per Million by Volume in
Natural Gas
mmHg = Vapor Pressure
Pas = Vapor Pressure
MH = MH* (Diagnostic Mode)
H/DVM = Digital Voltmeter (Diagnostic Mode)
FH = FH* (Diagnostic Mode)
Dew Point
Dew Point
Dew Point
Rel. Humidity
H
2
O
H
2
O
H
2
O
H
2
O/MMSCF IG
H
2
O/MMSCF NG
H
2
O (Nat. Gas)
Vapor Pressure
Vapor Pressure
H
2
O
Moisture DVM
MIS Probe
°C
°F
K
%
ppm
v
ppm
w
ppb
v
lbs
lbs
ppm
v
mmHg
Pas
MH
VDC
FH
Temperature
T/°C = Degrees Celsius default
T/°F = Degrees Fahrenheit
T/K = Kelvin
T/DVM = Digital Voltmeter (Diagnostic Mode)
Temperature
Temperature
Temperature
Temp DVM
°C
°F
K
VDC
Pressure
PSIg = Pounds per Square Inch Gauge default
Bars = Bars
mbs = Millibars
mm/Hg = Millimeters of Mercury
Pa(g) = Pascal, gauge
kPas(g) = KiloPascal, gauge
P/mV = Pressure in millivolts
P/DVM = Digital Voltmeter (Diagnostic Mode)
FP = FP** (Diagnostic Mode)
Pressure
Pressure
Pressure
Pressure
Pressure
Pressure
Pressure
Pressure DVM
MIS Probe
PSIg
Bars
mbs
mmHg
Pas
kPas
mV
VDC
FP
Auxiliary 1
Aux1/V = Volts default
Aux1/I = Milliamps
Aux1/User = Function (Displays Aux Label)
Aux1
Aux1
Aux1 (Aux Label)
VDC
mA
none
Auxiliary 2
Aux2/V = Volts default
Aux2/I = Milliamps
Aux2/User = Function (Displays Aux Label)
AuxX
Aux2
Aux2 (Aux Label)
VDC
mA
none
Volt Reference
Vref = Volts default (Diagnostic Mode)
Voltage Reference
VDC
Signal Ground
Vgnd = Volts default (Diagnostic Mode)
Signal Ground
VDC
User