Table 8. Correcting Alarm Conditions
Event Log Entry
Generating Condition
Clearing Condition or Action
System Error Please Reboot
Unit encounters something
that causes a system error.
•
Reboot the radio. If condition
continues after reboot, contact
factory Technical Services.
Network Interface Error
Ethernet interface fails to
operate.
•
Contact factory Technical
Services for assistance.
Radio Synth Out of Lock
Internal alarm caused by
the radio module.
•
Contact factory Technical
Services for assistance.
Radio Not Calibrated
Calibration failure on the
radio.
•
Contact factory Technical
Services for assistance.
Setting Frequency Failed
Radio has failed to set
configured frequencies.
•
Toggle frequencies or reboot. If
persistent contact Technical
Services for assistance.
OTA Sync Lost
Mobile Radio has lost
synchronization with the
Base Radio.
•
Ensure wireless connection is
free of obstacles and antennas
are properly installed.
•
Ensure that time
synchronization is valid on the
Base as synchronization lost
on the Base will also cause this
alarm to occur on the Mobile.
•
Ensure that STFP messages
traffic is present or beacons are
enabled on the Base.
PA Temperature Too HOT
Temperature of the PA
exceeds limits.
•
Ensure radio’s environment is
within specified range.
•
Ensure radio is installed with
ventilation to allow for cooling.
Time Synchronization
Invalid:
Radio cannot synchronize
with a time source or
configuration is invalid.
•
If this is the first time booting
up the radio, configure the
necessary time source
information.
•
Ensure that GPS/PTP
configurations are properly
configured.
•
Ensure that Ethernet/RF
connections to the radio are
correct.
High Reflected Power Set
SWR exceeds proper
operational limits.
•
Ensure proper antenna and
equipment are installed.