GE JV347IFWW Owner'S Manual And Installation Instructions Download Page 6

BEFORE YOU BEGIN

Installation  

Range Hood 

 

Instructions

 

 

Read these instructions completely and carefully .

 

IMPORTANT –

 

Save these instructions for 

local inspector’s use .

 

IMPORTANT –

 

Observe all governing 

codes and ordinances .

• 

Note to Installer –

 

Be sure to leave these 

instructions with the Consumer .

• 

Note to Consumer –

 

Keep these instructions 

for future reference .

•  Skill level –

 Installation of this appliance requires 

basic mechanical and electrical skills .

•  Completion time –

 30 minutes–3 hours

  Proper installation is the responsibility of the installer . 

  Product failure due to improper installation is not 

covered under the Warranty .

NOTE: Read the ductwork sections only if you do not 

have existing ductwork. If you have existing ductwork, 

skip to the “Damage” section and proceed.

WARNING – 

TO REDUCE THE RISK OF FIRE AND 

TO PROPERLY EXHAUST AIR, BE SURE TO DUCT AIR OUTSIDE—

DO NOT VENT EXHAUST AIR INTO SPACES WITHIN WALLS OR 

CEILINGS OR INTO ATTICS, CRAWL SPACES OR GARAGES.

The venting system must exhaust to the outside.

This hood can be vented vertically through upper cabinets or 

horizontally through an outside wall . Ductwork is not included .

Exhaust connection: 

The hood exhaust has been designed to mate with 

standard 3

1

4

 x 10

 rectangular ducting or 7

 diameter 

round ducting .

If a 6

 round duct is required, a rectangular-to-round 

transition adaptor must be used* . 

Do not use less than a 

6

 diameter duct.

Maximum duct length: 

For satisfactory air movement, the total duct length 

of a 3

1

4

 x 10

 rectangular, 6

 or 7

 diameter round 

duct 

should not exceed 65 equivalent feet. See 

the WORKSHEET–CALCULATE TOTAL EQUIVALENT 

DUCTWORK LENGTH section.
NOTE: 

It is important that ducting be installed using the 

most direct route and with as few elbows as possible . 

This ensures clear venting of exhaust and helps prevent 

blockages . Also, make sure dampers swing freely and 

nothing is blocking the ducts . When applicable, install any 

makeup (replacement) air system in accordance with local 

building code requirements . Visit 

GEAppliances.com

 for 

available makeup air solutions .

Elbows, transitions, wall and roofcaps, etc.,

 

present additional resistance to airflow and are equivalent 

to a section of straight duct longer than their actual 

physical size . When calculating the total duct length, add 

the equivalent lengths of all transitions and adaptors plus 

the length of all straight duct sections . The charts on the 

following pages show you how to calculate total equivalent 

ductwork length using the approximate feet of equivalent 

length of some typical ducts .

DUCTWORK REQUIREMENTS

WARNING –

 

Before beginning the 

installation, switch power off at service panel and  

lock the service disconnecting means to prevent power  

from being switched on accidentally . When the service 

disconnecting means cannot be locked, securely fasten 

a prominent warning device, such as a tag, to the 

service panel .

FOR YOUR SAFETY:

Questions?

 

Visit our Website at:

 

GEAppliances.com

6

*

 

 IMPORTANT: 

If a rectangular-to-round 

transition adaptor is used, the bottom 

corners of the damper will have to be 

cut to fit, using the tin snips, in order  

to allow free movement of the damper .  

Equivalent lengths of duct pieces  

are based on actual tests and reflect 

requirements for good venting 

performance with any hood .

Summary of Contents for JV347IFWW

Page 1: ......

Page 2: ...es do not go out immediately EVACUATE AND CALL THE FIRE DEPARTMENT B NEVER PICK UP A FLAMING PAN You may be burned C DO NOT USE WATER including wet dishcloths or towels a violent steam explosion will...

Page 3: ...dance with local building code requirements Visit GEAppliances com for available makeup air solutions C When cutting or drilling into wall or ceiling do not damage electrical wiring and other hidden u...

Page 4: ...ou do However the grease filter should be cleaned at least once a month To remove Pull down on the center of the front edge of the filter The filter will then slip out of the retaining tabs on the bac...

Page 5: ...l filter that helps remove smoke and odors The charcoal filter should be replaced after 6 to 12 months depending on hood usage To remove Pull down on the center of the front edge of the filter The fil...

Page 6: ...hould not exceed 65 equivalent feet See the WORKSHEET CALCULATE TOTAL EQUIVALENT DUCTWORK LENGTH section NOTE It is important that ducting be installed using the most direct route and with as few elbo...

Page 7: ...nd 9 Ft x Ft 45 elbow 7 Round 28 Ft x Ft wall cap 21 ft w o with damper x Ft damper 7 Round 39 Ft x Ft roof cap 7 Round 1 Ft x Ft to 31 4 x 10 rect transition 7 Round 5 Ft x Ft to 31 4 x 10 rect trans...

Page 8: ...INSTALLATION PARTS INCLUDED MOUNTING SPACE NOTES Hood width may be greater than the width of the range or cooktop but it may not be smaller Ensure the range or cooktop is installed per manufacturer s...

Page 9: ...7 Round A C B Recirculating non vented ductless D Installation Instructions CHOOSE VENT OPTION Determine the vent option that your installation will require and that is available for your model from t...

Page 10: ...s to be recirculated skip to the next step Remove the baffle from the top of the hood Reinstall the baffle so the short side marked VENTED is visible The long side of the baffle should be inside the h...

Page 11: ...ivot depending on installation FOR 7 ROUND VERTICAL DUCTED DISCHARGE INSTALLATIONS ONLY Bend up the duct alignment ears in preparation for later attachment of the 7 duct 6 7 Installation Instructions...

Page 12: ...shims must be a minimum of 3 8 thick and cut to fit the width of the inner recessed cabinet bottom 95 8 13 8 33 4 1 2 A Outside top exhaust Vertical duct 3 1 4 x 10 Rectangular Use the diagram or the...

Page 13: ...nt ears Use duct tape to make joints secure and airtight Duct tape 13 Attachment ear tabs 7 round duct SECURE HOOD Slide the hood back against the wall Tighten the mounting screws Be sure the screw he...

Page 14: ...or restrictive wall or roof cap If the hood seems to make excessive noise Fan may be hitting the filter Turn off the fan and remove the filter Bend the filter down slightly in the center into a dome...