14
INSTALL LIGHT BULB
NOTE:
A light bulb is not shipped with the hood .
Obtain one locally . Purchase and install an
incandescent light bulb with an ordinary screw
base, not more than 60 Watts, or a Compact
Fluorescent (CFL) light bulb with an ordinary
screw base,
not more than 13 Watts.
IMPORTANT:
For installation, handling and disposal
precautions, refer to the fluorescent bulb packaging literature.
14
Installation Instructions
TROUBLESHOOTING CHECKLIST
If the hood seems to be operating at high speed when
the control is not set on high, or if ventilation seems
inadequate, check the following:
❏
Knockouts not removed from hood .
❏
Damper blade not opening .
❏
Reduced airflow because the duct is too small or the
duct length is too long .
❏
The duct is blocked .
❏
Undersized or restrictive wall or roof cap .
If the hood seems to make excessive noise:
❏
Fan may be hitting the filter . Turn off the fan and
remove the filter . Bend the filter down slightly in the
center (into a dome shape) to allow fan clearance .
Reinstall and adjust as needed .
The fan does not work but the lights do:
❏
Switch power off at the service panel and lock the
service disconnecting means to prevent power from
being switched on accidentally . When the service
disconnecting means cannot be locked, securely
fasten a prominent warning device, such as a tag, to
the service panel .
❏
Check the wiring connections . See the
CONNECT
WIRING
section in these Installation Instructions .
REPLACE FILTER
Make sure fan blade turns freely and replace the
filter .
NOTE:
Install the metal grease filter if ducted or
the charcoal filter if recirculated .
The installation is complete . Turn on power at service
panel, and test for proper operation .
Metal grease filter or charcoal filter
15
Summary of Contents for JV347IFWW
Page 1: ......