10
REMOVE EXHAUST ADAPTOR
If exhausting/venting using the 3
1
⁄
4
″
x 10
″
rectangular
duct
Remove the exhaust adaptor from the inside of the hood.
Set it aside along with its mounting screws .
3
1
⁄
4
″
x 10
″
rectangular
exhaust
adaptor
and screws
REMOVE FILTER
Remove the shipping tape holding the
metal grease
filter
in place . Pull down on the center of the front edge
of the filter . The filter will then slip out of the retaining
tabs on the back .
REVERSE THE BAFFLE FOR
DUCTED INSTALLATIONS ONLY
If the hood is to be recirculated, skip to the next step.
Remove the baffle from the top of the hood . Reinstall
the baffle so the short side marked “VENTED” is visible .
The long side of the baffle should be inside the hood .
2
3
4
Metal grease filter
Installation Instructions
“VENTED” is visible
REMOVE DUCT KNOCKOUT
If
recirculating
, non-vented ductless
skip to Step 9 D and proceed.
Using a flat-blade screwdriver, remove the appropriate
duct knockout
from the top or back of the hood .
3
1
⁄
4
″
x 10
″
Rectangular
vertical discharge.
Remove top rectangular
duct knockout only .
7
″
Round vertical discharge.
Remove circular duct
knockout only .
3
1
⁄
4
″
x 10
″
Rectangular horizontal
discharge.
Remove rear
rectangular duct knockout only .
5
Summary of Contents for JV347IFWW