![GE Homespring UF 100 Operation Manual Download Page 9](http://html.mh-extra.com/html/ge/homespring-uf-100/homespring-uf-100_operation-manual_134525009.webp)
Backpulse
Tank
Digital Air
Pressure
Gauge
Valve Cap
fiGUrE 11
fiGUrE 10
Mark mounting hole
locations
Anchor this hole of the Bracket
assembly to the wall stud first
36” Vertical
Clearance
FigUre 9
•
Swing opposite end of the Bracket assembly
upward. Level the Bracket. Mark the locations of
the remaining three anchoring bolts with a pen
or pencil.
•
Lower the unattached end of the Bracket
assembly back to the floor.
•
Pre-drill the three holes for the remaining three
2½” anchoring bolts at the marked locations.
•
Lift Bracket assembly up again, insert the
three 2½” anchoring bolts, and tighten all four
anchoring bolts.
Wall MOUnTinG
The Bracket assembly must be mounted directly
to the wall studs or the two pieces of 2x4 lumber
installed earlier. The four 2½” wall-mounting
anchoring bolts are for wood studs only. If the wall
is made of concrete, use appropriate concrete
bolts for this installation.
•
Mark the first hole location on the stud or lumber.
Ensure that all spacing requirements are
satisfied.
•
Drill a hole suitable for the supplied 2½”
anchoring bolt.
•
Leaving one end of the Bracket assembly on the
ground for support, lift the opposite end of the
Bracket up, align the top mounting hole on the
Bracket assembly with the pre-drilled hole on the
wall stud, and secure the Bracket assembly with
one 2½” anchoring bolt. Do not tighten this bolt
completely.
4
b
The System is shipped fully assembled, except for
the System Base. Attach the System Base to the Back-
pulse Tank, using the supplied
3/8” bolts and washers.
1
The Backpulse Tank has been pre-pressurized to ap-
proximately 30-35 psi from the factory. Confirm the Backpulse
Tank pressure. If the Backpulse Tank pressure is less than 30
psi, add air using a pump. Recheck the pressure after 15 min-
utes to ensure that there are no leaks in the Backpulse Tank.
3
The pressure may require adjustment depending
on the water system of the home. Refer to the Table below
to ensure proper tank pressure. Air can be added or
released from the Air Bladder Valve as required.
4
NOTE: For
UFC 207, UF 207, UFC 209, UF 209, UFC
211, and UF 211 models
, cut open the plastic bag before
standing the System upright.
Stand the System upright carefully.
2
WARNING!
Handle the System with care. The outside surfaces of the
System may be slippery with a food-grade preservative
used in the manufacturing process.
System installation
9
WARNING!
If the Backpulse Tank has less than 20 psi of pressure, the
integrity test will fail.
Only check the Backpulse Tank when the System is
depressurized.