Parameter
U
f
C 100
U
f
100
U
f
100 with
Surface W
ater
Option Kit
U
f
C 207/ U
f
207
U
f
C 209/ U
f
209
U
f
C 21
1/ U
f
21
1
Recommended maximum peak flow
rate¹ (US gallons per minute/ litres per minute)
9 gpm (34 Lpm)
9 gpm (34 Lpm)
9 gpm (34 Lpm)
6 gpm (22.5 Lpm)
9 gpm (34 Lpm)
1
1 gpm (42 Lpm)
Maximum continuous flow rate
4.5 gpm (17Lpm)
4.5 gpm (17Lpm)
4.5 gpm (17Lpm)
4.5 gpm (17Lpm)
4.5 gpm (17Lpm)
4.5 gpm (17Lpm)
Pressure drop at maximum continuous
flow rate when new
, at 25°C²
4 psi (27.6 kPa)
3.5 psi (24 kPa)
5 psi (35 kPa)
10 psi (69kPa)
7 psi (48 kPa)
5 psi (35 kPa)
Annual water volume treatment
capacity³ (US gallons)
100,000 gal.
(378,000 litres)
100,000 gal.
(378,000 litres)
100,000 gal.
(378,000 litres)
65,000 gal. (245,700 litres)
100,000 gal. (378,000
litres)
130,000 gal. (491,400 litres)
GAC water volume capacity at maximum continuous flow rate
(US gallons)
130,000 gal. (491,400 litres)
N/A
N/A
65,000 gal. (245,700 litres)
130,000 gal. (491,400 litres)
130,000 gal. (491,400 litres)
Maximum working pressure
100 psi (690 kPa)
100 psi (690 kPa)
100 psi (690 kPa)
100 psi (690 kPa)
100 psi (690 kPa)
100 psi (690 kPa)
Minimum working pressure
30 psi (207 kPa)
30 psi (207 kPa)
30 psi (207 kPa)
30 psi (207 kPa)
30 psi (207 kPa)
30 psi (207 kPa)
Maximum water temperature
100°F (38°C)
100°F (38°C)
100°F (38°C)
100°F (38°C)
100°F (38°C)
100°F (38°C)
Minimum water temperature
>32°F (>0°C)
>32°F (>0°C)
>32°F (>0°C)
>32°F (>0°C)
>32°F (>0°C)
>32°F (>0°C)
Maximum ambient temperature
120°F (49°C)
120°F (49°C)
120°F (49°C)
140°F (60°C)
140°F (60°C)
140°F (60°C)
Minimum ambient temperature
>32°F (> 0°C)
>32°F (> 0°C)
>32°F (> 0°C)
>32°F (> 0°C)
>32°F (> 0°C)
>32°F (> 0°C)
Operating pH range
6 - 10.5
6 - 10.5
6 - 10.5
6 - 10.5
6 - 10.5
6 - 10.5
Flush volume per day
5
10 - 20 gal.
(38 - 75.6 litres)
10 - 20 gal.
(38 - 75.6 litres)
7.5 - 19.5 gal
(28.4 - 73.7 litres)
7.5 - 19.5 gal
(28.4 - 73.7 litres)
7.5 - 19.5 gal
(28.4 - 73.7 litres)
7.5 - 19.5 gal
(28.4 - 73.7 litres)
System efficiency
92% - 96%
92% - 96%
94% - 97%
87% - 94%
4
92% - 96%
4
94% - 97%
4
Controller voltage
24 V
AC
24 V
AC
24 V
AC
24 V
AC
24 V
AC
24 V
AC
Inlet port (female)
3/4 - 14 NPT
3/4 - 14 NPT
3/4 - 14 NPT
3/4 - 14 NPT
3/4 - 14 NPT
3/4 - 14 NPT
Outlet port (female)
3/4 - 14 NPT
3/4 - 14 NPT
3/4 - 14 NPT
3/4 - 14 NPT
3/4 - 14 NPT
3/4 - 14 NPT
Drain port (female)
3/4 - 14 NPT
3/4 - 14 NPT
3/4 - 14 NPT
1/2 - 14 NPT
1/2 - 14 NPT
1/2 - 14 NPT
V
ertical mount footprint: inches (cm)
18 X 18 (45 X 45)
18 X 18 (45 X 45)
18 X 18 (45 X 45)
18 X 18 (45 X 45)
18 X 18 (45 X 45)
18 X 18 (45 X 45)
V
ertical mount installation height: inches
(cm)
74 (188)
74 (188)
74 (188)
68 (173)
74 (188)
74 (188)
Horizontal mount footprint: inches (cm)
N/A
N/A
N/A
24 X 68 (61 X 173)
24 X 74 (61 X 188)
24 X 74 (61 X 188)
Horizontal mountinstallation height:
inches (cm)
N/A
N/A
N/A
36 (91)
36 (91)
36 (91)
Shipping weight
1
15 lbs (52.3 kg)
1
10 lbs (50 kg)
120 lbs (54.5 kg)
76 lbs (34.5 kg.)
79 lbs (36 kg.)
82 lbs (37.3 kg.)
Shipping dimensions W X H X L
inches
(cm)
16 X 17.3 X 75.5
(40.6 X 43.8 X 191.8)
16 X 17.3 X 75.5
(40.6 X 43.8 X 191.8)
16 X 17.3 X 75.5
(40.6 X 43.8 X 191.8)
15.5 X 16 X 72.5 (39.4
X 40.6 X 184.2)
15.5 X 16 X 72.5
(39.4 X 40.6 X 184.2)
15.5 X 16 X 72.5 (39.4 X 40.6 X
184.2)
1 - Chlorine reduction claims are based on a continuous flow of
4.5 gpm.
2 - Pressure drops are given for systems when they are new and
equipped as specified by the model number
.
At temperatures below 25°C the pressure drop will be
higher and at temperatures higher than 25°C the pressure drop
will be lower
.
3 -
Annual water volume capacity is dependent on water quality
.
4 -
All the UF 200 Systems are equiped with a controller that can
operate the flush/drain sequence from once per day to once per
hour
.
The efficiency numbers assume
that the flush program is run once per day
.
5 - Flush volumes are based on a drain flow rate of 5 US gpm.