background image

WARNING: 

RISK OF FIRE

• To reduce the risk of severe injury or death, follow all installation 

instructions.

‡$SSOLDQFHLQVWDOODWLRQPXVWEHSHUIRUPHGE\DTXDOL¿HGLQVWDOOHU

• Install the appliance according to these instructions and in accordance 

with local codes.

• This appliance must be exhausted to the outdoors.
• Use only 4” rigid metal ducting for exhausting the clothes dryer to the 

outdoors.

• 

DO NOT

LQVWDOODFORWKHVGU\HUZLWKÀH[LEOHSODVWLFGXFWLQJPDWHULDOV

,I ÀH[LEOH PHWDO VHPLULJLG RU IRLOW\SH GXFW LV LQVWDOOHG LW PXVW EH

UL listed and installed in accordance with the instructions found 

in “Connecting The Dryer To House Vent” on page 8 of this manual. 

Flexible venting materials are known to collapse, be easily crushed, 

DQGWUDSOLQW7KHVHFRQGLWLRQVZLOOREVWUXFWGU\HUDLUÀRZDQGLQFUHDVH
WKHULVNRI¿UH

• Do not install or store this appliance in any location where it could be 

exposed to water and or weather.

‡6DYHWKHVHLQVWUXFWLRQV,QVWDOOHUV%HVXUHWROHDYHWKHVHLQVWUXFWLRQV

ZLWKWKHFXVWRPHU

NOTE: Installation and service of this appliance requires basic 
mechanical and electrical skills. It is your responsibility to 

FRQWDFWDTXDOL¿HGLQVWDOOHUWRPDNHWKHHOHFWULFDOFRQQHFWLRQV

Installation
Instructions

Unitized Electric 

Washer/Dryer

Questions on Installation? Call: 1-800-GECARES (US) 

RU9LVLWRXU:HEVLWHDW

www.GEAppliances.com (US).

In Canada, call 

800.561.3344

 

or visit

 www.GEAppliances.ca

BEFORE YOU BEGIN

Read these instructions completely and 

carefully.

•   

IMPORTANT-

 Save these instructions for 

local inspector’s use.

•   

IMPORTANT-

 Observe all governing codes 

and ordinances.

•   

Note to Installer -

 %H VXUH WR OHDYH WKHVH

instructions with the customer.

•   

Note to Customer -

 Keep these instructions with 

your Owner’s Manual for future reference.

‡%HIRUHWKHDSSOLDQFHLVUHPRYHGIURPVHUYLFHRU

discarded, remove the washer and dryer doors.

•   Inspect the dryer exhaust outlet and straighten 

the outlet walls if they are bent.

•   Service information and the wiring diagram are 

located at the access panel.

•   Do not allow children on or in the appliance. 

Close supervision of children is necessary when 

the appliance is used near children.

•   Install the appliance where the temperature is 

above 50°F 

ƒ&

for satisfactory operation of 

the control system.

• 

  Product failure due to improper installation is not 

covered under the Warranty.

TOOLS YOU WILL NEED

Slip Pliers

Phillips Screwdriver

)ODWEODGH6FUHZGULYHU

µ1XWGULYHU

Level

GLOVES

SAFETY

GLASSES

APPLIANCE POWER

CORD KIT

(NOT PROVIDED)

4" DUCT

CLAMPS (2)

OR

4" SPRING

CLAMPS (2)

EXHAUST

HOOD

3/4" STRAIN

RELIEF

UL RECOGNIZED

4" DIA. METAL

ELBOW

DUCT TAPE

UL RATED 
120/240V,30A       
WITH 3 OR 4 PRONGS. 
IDENTIFY THE PLUG 
TYPE AS PER THE 
HOUSE RECEPTACLE 
BEFORE PURCHASING 
LINE CORD. 

4" DIA. FLEXIBLE METAL (SEMI-RIGID)

UL LISTED TRANSITION DUCT

(IF NEEDED)

 KIT WX08X10077 (INCLUDES 2 ELBOWS)

4" DIA. METAL DUCT

(RECOMMENDED)

4" DIA. FLEXIBLE METAL (FOIL TYPE)

UL LISTED TRANSITION DUCT

(IF NEEDED.)

4" COVER PLATE (IF NEEDED)

(KIT WE1M454)

PARTS SUPPLIED

2 Rubber 
Washers

6WDLQHU6FUHHQV

Rubber Washers

ZDVKHUVPD\EHLQZDWHUKRVHV

2 Washer Hoses

&DEOH7LH

MATERIALS YOU WILL NEED

233D1835P004

31-16728

  

12-14  GE

 

Printed in Mexico

Summary of Contents for GUD27ESMMW

Page 1: ...d carefully IMPORTANT Save these instructions for local inspector s use IMPORTANT Observe all governing codes and ordinances Note to Installer H VXUH WR OHDYH WKHVH instructions with the customer Note...

Page 2: ...ing prong from the power cord Follow national electrical codes and ordinances This appliance must be supplied with the voltage DQG IUHTXHQF LQGLFDWHG RQ WKH UDWLQJ SODWH ORFDWHG DW WKH WRS RI WKH GU H...

Page 3: ...can be adjusted 375 74 5 Vent Drain outlet UHDU 4 2 8 2 2 2 75 Gas Inlet 5HDU YLHZ RI DSSOLDQFH Water Inlets UHDU Dimension represents door closed including handle and knobs NOTE With feet set at mid...

Page 4: ...ed In the event of malfunction or breakdown grounding will reduce the risk of electric shock by providing a path of least resistance of electric current This appliance is HTXLSSHG ZLWK D FRUG KDYLQJ D...

Page 5: ...H RQ QHZ FRQVWUXFWLRQ 127 IRU XVH RQ UHFUHDWLRQDO YHKLFOHV 127 IRU XVH LQ DUHDV ZKHUH ORFDO FRGHV SURKLELW JURXQGLQJ through the neutral conduction 7XUQ R WKH FLUFXLW EUHDNHU V DPS RU UHPRYH WKH dryer...

Page 6: ...T INFORMATION WARNING IN CANADA AND IN THE UNITED STATES THE REQUIRED EXHAUST DUCT DIAMETER IS 4 IN 102mm DO NOT USE DUCT LONGER THAN SPECIFIED IN THE EXHAUST LENGTH TABLE 8VLQJ H KDXVW ORQJHU WKDQ VS...

Page 7: ...the more the unit will vibrate STANDARD REAR EXHAUST 9HQWHG DERYH RRU OHYHO 2 5 200 1 5 200 1 21 85 7 21 72 0 1 0 867 2 NOTE ELBOWS WILL PREVENT DUCT KINKING AND COLLAPSING WARNING TO REDUCE THE RISK...

Page 8: ...s UL LISTED FLEXIBLE METAL FOIL TYPE TRANSITION DUCT In special installations it may be necessary to connect the GU HU WR WKH KRXVH YHQW XVLQJ D H LEOH PHWDO IRLO W SH GXFW 8 OLVWHG H LEOH PHWDO IRLO...

Page 9: ...WARNING Be sure not to pull or damage the electrical wires inside the dryer when inserting the duct 4 UL approved rigid metal DUCT TAPE 27 MODELS ONLY DRYER EXHAUST TO RIGHT LEFT OR BOTTOM CABINET WA...

Page 10: ...coupling and clamps provided in the machine must be used and in addition a siphon break MUST be installed on the back of the machine Obtain and use a siphon break kit and follow the instructions in th...

Page 11: ...ATION If your appliance is approved for installation in an alcove or closet it will be stated on a label on the appliance back 72 35 9 17 5 028176 2 17 1 02 6785 520 808 7 1 1 72 0 17 1 5 1 1 7 6 0 1...

Page 12: ...IMPROPER AND DANGEROUS OPERATION AFTER SERVICING INSTALLATION For replacement parts and other information refer to Owner s Manual for servicing phone numbers 5 67 5 285 1 33 1 72 5 9 1 03257 17 352 8...

Page 13: ...Rondellesen Caoutchouc Rondelles en caoutchouc OHV MRLQWV SHXYHQW HQWUH GDQV OHV WX DX D HDX 2 tuyaux de la laveuse 1 collier en plastique AVANT DE COMMENCER Lisez les instructions compl tement et ave...

Page 14: ...V HVW VX VDQWH HW DSSDUHLO ne devrait pas tre install sur untapis ou expos au climat PLOMBERIE 35 66 21 8 OOH GRLW rWUH GH SVL PLQLPXP HW 120 psi maximum 7 03 5 785 8 OH FKDX H HDX GH YRWUH PDLVRQ GRL...

Page 15: ...ons en pieds correspondant 375 8 2 17 9 32 7 27 325 19 1 DIMENSIONES NOMINALES DU PRODUIT 27 75 5 52 9 3 9 26 8 36 5 26 7 47 Dimensions lorsque les portes sont ferm es incluant les poign es et les bou...

Page 16: ...ence GH QRUPHV ORFDOHV FRQIRUPpPHQW 8 1250 6 75 48 6 1 7 21 6 16 1 3 12 RX D 1RUPH pOHFWULTXH FDQDGLHQQH 6 CONDITIONS ELECTRIQUES Cet appareil doit tre branch une prise lectrique LQGLYLGXHOOH SURWpJpH...

Page 17: ...ilis e dans les nouvelles constructions Ne peut pas tre utilis e dans les v hicules r cr atifs Ne peut pas tre utilis e dans les r gions o les codes locaux LQWHUGLVHQW OD PLVH j OD WHUUH SDU OH ELDLV...

Page 18: ...e ignor Deux coudes de 45 devraient tre trait s comme un coude de 90 Chaque coude de plus de 45 devrait tre trait comme un coude de 90 SCELLAGE DES JOINTS 7RXV OHV MRLQWV GHYUDLHQW rWUH VHUUpV SRXU pY...

Page 19: ...ARRIERE STANDARD Ventil au dessous du niveau du sol 5 METTRE A NIVEAU ET STABILISER VOTRE APPAREIL Mettre niveau et stabiliser votre appareil pSODFH SUXGHPPHQW O DSSDUHLO YHUV VD SRVLWLRQ QDOH DODQFH...

Page 20: ...les il peut tre n cessaire de EUDQFKHU OD VpFKHXVH j O DpUDWLRQ GH OD PDLVRQ XWLOLVDQW XQ WX DX H LEOH HQ PpWDO DOXPLQLXP 8Q WX DX 8 H LEOH HQ PpWDO VHPL ULJLGH QH SHXW SDVrWUH XWLOLVp 7 FHFL R XQ dia...

Page 21: ...anchez le coude interne AVERTISSEMENT Assurez vous de ne SDV WLUHU RX HQGRPPDJHU OHV OV pOHFWULTXHV j O LQWpULHXU de la s cheuse lorsque vous ins rez le tuyau UNIQUEMENT POUR MODELES DE 27 PO ECHAPPEM...

Page 22: ...areil doivent tre utilis s et GH SOXV XQ EULVH VLSKRQ 2 7 rWUH LQVWDOOp DX GRV GH OD PDFKLQH 2EWHQLU HW XWLOLVHU XQ NLW EULVH VLSKRQ HW VXLYH OHV LQVWUXFWLRQV GX NLW 7 BRANCHER LA PLOMBERIE QVWDOOH VL...

Page 23: ...YRWUH DSSDUHLO HVW DXWRULVp SRXU XQH LQVWDOODWLRQ GDQVXQ emplacement ou un meuble cela sera indiqu sur laplaque au dos de l appareil 3285 9 7 5 81 5 1 120 5 3 8 6 7 80 7 86 6 3 5 808 7 21 7 3285 0 17...

Page 24: ...T APRES REPARATION ET D INSTALLATION Pour les pi ces de rechange et autres informations veuillez reporter au Manuel de l Utilisateur pour les num ros de t l phone du service apr s vente 15 675 9275 12...