– 57 –
Resistance can be measured at the J701 main
board connecter. Make sure to unplug the connector
to isolate the thermistor before taking resistance
readings. To determine the temperature of the
incoming water, the main control measures the
GLႇHUHQFHEHWZHHQWKHYROWDJHVHQWDQGWKH
voltage returned from the thermistor. The main
board then makes temperature adjustments
accordingly.
7KHPDLQFRQWUROVKRXOG¿OOWKHWXEZLWKZDWHU
/- 10°F to 15°F of set temperature by
opening or closing the hot and cold water valves.
The Automatic Temperature Control (ATC) is a
feature that utilizes a thermistor to regulate the
ZDWHU¿OOWHPSHUDWXUH
The thermistor has a negative temperature
FRHႈFLHQWDVWHPSHUDWXUHLQFUHDVHVUHVLVWDQFH
decreases).
The thermistor is located in the outlet of the
¿OOIXQQHODQGZLOOPHDVXUH.
:
at room
temperature (77°F / 25°C).
If the thermistor reads outside the expected range
(10k to 120k
:
), the main control will default to the
IROORZLQJSUHSURJUDPPHG¿OOWHPSHUDWXUHVHWWLQJV
between 60°F and 135°F:
Tap Cold
: Cold water valve only
Cold
: Cold water valve only
Cool
: Hot and cold water valves
Warm
: Hot and cold water valves
Hot
: Hot water valve only
:KHQERWKYDOYHVDUHHQHUJL]HGWKHLQWHUQDORUL¿FHV
LQWKHYDOYHVPHWHUWKHÀRZWRDFROGDQG
hot ratio.
With the lid open, ATC is deactivated.
Extreme water temperatures at low pressure can
cause the ATC to use its maximum number of
DFWLYDWLRQVDQGUHYHUWWRDSUHVHW¿OOURXWLQH7KH
main control will not allow the water valve to cycle
PRUHWKDQWLPHVSHU¿OO
(Continued Next Page)
ATC Temperature Chart
Temperature Setting
Water Temperature
Tap Cold
Cold Tap Water
Cold
60°F (+/- 10°F)
Cool
70°F (+/- 10°F)
Warm
80°F (+/- 10°F)
Hot
110°F (+/- 15°F)
Automatic Temperature Control (ATC)
Thermistor Resistance Table
Temp (
°
C)
Temp (
°
F)
Resistance (
:
)
10
50
96,369
15
59
78,033
20
68
61,918
28
82.4
43,754
32
90
37,286
38
100
28,987
44
111
22,954
50
122
18,223
54
130
15,672
66
150
10,196
76
169
7,265
Summary of Contents for GUD24ESSMWW
Page 16: ... 16 LUÀRZ ...
Page 75: ... 75 Fault Code Binary Display ...
Page 77: ... 77 LULQJ LDJUDPV To Washer Electric Dryer ...
Page 78: ... 78 OHFWULF U HU RQJ 9HQW ORZHU 0RWRU LUFXLW ...
Page 79: ... 79 To Washer Gas Dryer ...
Page 80: ... 80 Power Supply To Washer Personality Jumper Plugs Washer ...