Dryer Operation Overview
Air enters the dryer cabinet, passing through the heating elements (gas combustion chamber for gas
models), and into the drum. The hot air heats the wet clothes and gradually removes their moisture
in the form of water vapor. The moist air is vented through the dryer exhaust. Overall heating
temperature is regulated by means of two temperature thermostats: an inlet control thermostat located
near the heating elements and an outlet control thermostat located at the blower. (
NOTE
: Gas models
use only an outlet control thermostat for overall temperature regulation.) A safety thermostat, located
QHDUWKHKHDWLQJHOHPHQWVGLႇXVHUIRUJDVPRGHOVF\FOHVWKHKHDWLQJHOHPHQWVEXUQHUIRUJDV
models), if overheating occurs. Also, the high limit thermostat, located near the heating elements
GLႇXVHUIRUJDVPRGHOVSURYLGHVDGGLWLRQDOVDIHW\DQGLQWHUUXSWVPRWRUDQGKHDWHURSHUDWLRQLI
temperature rises above safe limits.
The typical dryer cycle progresses as follows:
1. A cycle is selected and the Start key is pressed.
2. The motor is activated.
3.
7KHKHDWHUFRLOVEXUQHUIRUJDVPRGHOVDUHDFWLYDWHG7KHFRLOVEXUQHUF\FOHRQDQGRႇWR
achieve the desired temperature throughout the heating portion of the cycle.
4. If an Auto Dry cycle is selected, the heater coils (burner for gas models) are activated. The coils
EXUQHUF\FOHRQDQGRႇXQWLOWKHORDGKDVDFKLHYHGWKHGHVLUHGGU\QHVVOHYHO
5. If timed drying is selected, the heater coils (burner for gas models) are activated and cycle on and
RႇIRUWKHVHOHFWHGWLPHDWWKHVHOHFWHGWHPSHUDWXUH
6. The heater coils (burner for gas models) discontinue operation after the dryness level or elapsed
time has been achieved.
7.
7KHPRWRUFRQWLQXHVRSHUDWLQJXQWLOWKHFORWKHVWHPSHUDWXUHGURSVEHORZVSHFL¿HGWHPSHUDWXUH
(Cool Down).
Dryer Air Flow System
Dryer
Cabinet
'LႇXVHU
Drum
Lint trap
Blower
Exhaust
Safety Thermostat
Safety Thermostat
Inlet Control Thermostat
t°
t°
Outlet Control Thermostat
Heater
Pan/Electric
Elements
Gas
Combustion
Chamber
High Limit Thermostat
t°
High Limit Thermostat
t°
t°
t°
Summary of Contents for GUD24ESSMWW
Page 16: ... 16 LUÀRZ ...
Page 75: ... 75 Fault Code Binary Display ...
Page 77: ... 77 LULQJ LDJUDPV To Washer Electric Dryer ...
Page 78: ... 78 OHFWULF U HU RQJ 9HQW ORZHU 0RWRU LUFXLW ...
Page 79: ... 79 To Washer Gas Dryer ...
Page 80: ... 80 Power Supply To Washer Personality Jumper Plugs Washer ...