– 65 –
Knob Index/
Test number
Test Name
Description of test
UI Version
(Critical)
After entering this test, press the Start button to toggle through
the software version number as follows: (Example: v01.23)
Major Version
(Lid Locked LED ON).
1st Press
'LVSOD\LQELQDU\DOO/('VRႇ
2nd Press
: Display 1 in binary.
Minor Version
(Lid Locked LED OFF).
3rd Press
: Display 2 in binary.
4th Press
: Display 3 in binary.
UI Version
(Non-critical)
After entering this test, press the Start button to toggle through
the software version number as follows: (Example: v01.23)
Major Version
(Lid Locked LED ON).
1st Press
'LVSOD\LQELQDU\DOO/('VRႇ
2nd Press
: Display 1 in binary.
Minor Version (Lid Locked LED OFF).
3rd Press
: Display 2 in binary.
4th Press
: Display 3 in binary.
Hot Water
Valve
3UHVVLQJ6WDUWZLOOWRJJOHWKHKRWYDOYHRQDQGRႇ
Test will have a timeout for how long valve will be on (1 minutes).
7KHYDOYHZLOOWXUQRႇZKHQWKHWHVWLVH[LWHG
Cold Water
Valve
3UHVVLQJ6WDUWZLOOWRJJOHWKHFROGYDOYHRQDQGRႇ
Test will have a timeout for how long valve will be on (1 minutes).
7KHYDOYHZLOOWXUQRႇZKHQWKHWHVWLVH[LWHG
Pressure
Sensor
Pressing Start will start the test.
Pressure sensor test will have a timeout. All valves will turn on. All
LEDs will blink at start of test. Stop blinking LEDs as water levels
are crossed. The levels are: 2", 3", 4", 5", 6".
Drain Pump
3UHVVLQJ6WDUWZLOOWRJJOHWKHGUDLQSXPSRQDQGRႇ
Test will have a timeout for how long drain pump will be on (4
PLQXWHV7KHGUDLQSXPSZLOOWXUQRႇZKHQWKHWHVWLVH[LWHG
(Continued Next Page)
6
7
8
9
10
11
Summary of Contents for GUD24ESSMWW
Page 16: ... 16 LUÀRZ ...
Page 75: ... 75 Fault Code Binary Display ...
Page 77: ... 77 LULQJ LDJUDPV To Washer Electric Dryer ...
Page 78: ... 78 OHFWULF U HU RQJ 9HQW ORZHU 0RWRU LUFXLW ...
Page 79: ... 79 To Washer Gas Dryer ...
Page 80: ... 80 Power Supply To Washer Personality Jumper Plugs Washer ...