– 49 –
Note:
Condenser Fan Not Running
• Compressor and condensor fan should always operate at the same time.
• When no voltage at main control board,
Check fan for obstruction.
Unplug the refrigerator to
reset main control board.
Warm freezer thermistor
to 70 F. Reconnect
power and set
temperature controls to 5
and 5. Recheck voltage.
Is voltage correct?
YES
Adjust settings and allow
24 hours to stabilize.
NO
At the condenser
fan connector,
check for 13 VDC
.
Is voltage correct
for both?
YES
Replace condenser
fan motor.
NO
.
Check for 13 VDC
Is voltage correct for
both?
YES
Repair wiring between
main control board and
condenser fan motor.
NO
Replace main
control board.