– 2 –
G
R
O
U
N
D
20 TOP MOUNT GE™
DISCONNECT POWER CORD BEFORE SERVICING
Technical Data
IMPORTANT SAFETY NOTICE
238C4518P001
IMPORTANT - RECONNECT ALL GROUNDING DEVICES
All parts of this appliance capable of conducting electrical cur-
rent are grounded. If grounding wires, screws, straps, clips, nuts
or washers used to complete a path to ground are removed
for service, they must be returned to their original position and
properly fastened.
ELECTRICAL SPECIFICATIONS
Temperature Control (Position FF/FZ) ...................................................37/0°F
Defrost Control (w/no door openings) ............................. 10hrs @ 35 min
Overtemperature Thermostat .............................................................. 63-57°F
Electrical Rating: 115V AC 60 Hz .....................................................11.6 Amp
Maximum Current Leakage .................................................................. 0.75 mA
Maximum Ground Path Resistance ............................................. 0.14 Ohms
NO LOAD PERFORMANCE
Control Position 5/5 and Ambient of 70°F to 90°F
Fresh Food, °F ............................................................................................ 34 to 40
Frozen Food, °F ............................................................................................. -3 to 3F
Run Time, % @ 70°F .................................................................................. 20 to 40
Run Time, % @ 90°F .................................................................................. 40 to 70
This information is intended for use by individuals possessing
adequate backgrounds of electrical, electronic and mechanical
experience. Any attempt to repair a major appliance may result
in personal injury and property damage. The manufacturer or
seller cannot be responsible for the interpretation of this informa-
tion, nor can it assume any liability in connection with its use.
REFRIGERATION SYSTEM
Compressor ........................................................................................... 700 BTU/hr
Minimum Compressor Capacity .............................................. 22 inches Hg
Minimum Equalized Pressure
@ 70°F ................................................................................................. 40 to 45
PSIG
@ 90°F ................................................................................................. 48 to 60
PSIG
REFRIGERANT CHARGE (R134a)
20 TMNF models ................................................................................ 4.00 ounces
AIR FLOW
EVAPORATOR
COLD AIR
MIXED AIR
AIR RETURN TO
FREEZER
.105”
TO CABINET
WIRING
ORANGE
BLACK
GREEN/YELLOW
EVAPORATOR
FRESH FOOD
COMPRESSOR
REV. 0
Summary of Contents for GTRS0 Series
Page 2: ......
Page 5: ...3...
Page 7: ...5 MODEL NOMENCLATURE Model series GTRS0 GTRC0 GTRL0 MTRL0 20 cubic foot refrigerators...
Page 11: ...9...
Page 14: ...12 REMOVE FRESH FOOD DOOR LOWER HINGE WITH 5 16 SOCKET SCREWDRIVER REMOVE TWO NUTS...
Page 34: ...20 EXPLODED VIEWS Knob Electro mechanical EX PL OD ED VIE WS...
Page 35: ...21 Knob Electronic...
Page 36: ...22 structure...
Page 37: ...23 FREEZER DOOR FRESHFOOD DOOR...
Page 38: ...24 HINGE...
Page 39: ...25 RACKS SPILLPROOF...
Page 51: ...37 Schematic Knob Electro mechanical...
Page 54: ...40 COMPONENT AND CONNECTOR LOCATOR VIEWS...
Page 55: ...41 Relay and Overload Under Cover Compressor Dryer No Clean Condenser Capacitor Condenser Fan...