2.3
Setting the Operating Parameters
Input via the numeric keypad:
The desired value is entered via the numeric keypad. It is displayed on the respective line. If an
incorrect value is entered by mistake, the value can be deleted by pressing the
CL
key.
2.3.1
Exposure time
Press the
F4
e key. The set-point value display of the minutes/seconds is displayed inversely.
Enter the desired exposure time, confirm the set exposure time via the OK
key, and the
clock symbol e subsequently appears.
If
0 is entered as the time, the timer is switched off and the high voltage can only be
switched on and off via the X-RAY ON
and
X-RAY OFF
button.
(Special version for Australia:
0 cannot be entered, the input value must be greater than 0.0.
The maximum exposure time is 30 min.)