Operating Manual ERESCO MF4 Type Series
Copyright by GE Sensing & Inspection Technologies GmbH Bogenstrasse 41 D - 22926 Ahrensburg
Figures 2 and 5 display the front and side view of the digital control unit ERESCO MF4 control
.
It is advisable to carry out installation in the following order:
1. If necessary, use a support to position the radiating unit for exposure.
2. Connect the connecting cable to the radiating unit (
X1
).
3. If necessary, connect the water cooling pump or the water turbine flow rate monitor
to the control unit (
X4
).
4. Using the whole length of the connecting cable, position the control unit as far away from
the radiating unit as possible, facing away from the radiation; connect the connecting
cable to socket
X5
and the mains cable to socket
X1
. The plug connections are non-
interchangeable.
CAUTION !
Orange mains cable with "Schuko" plug 230 V AC only !
Grey mains cable without "Schuko" plug 115 V AC only !
2.
Operating Manual
Preliminary remarks: The following Operating Manual does not contain instructions
on adherence to obligatory radiation protection.
It is the responsibility of the user to equip operating personnel with
dosimeters and to monitor them, as well as to carry out any struc-
tural radiation protection measures.
With regard to exposure conditions for achieving minimum image
quality, we refer to relevant DIN regulations.
2.1 Installation of the Unit
The connection diagram in Fig. 1 and the connection plan in Appendix 2 display the
necessary connections.
Fig. 1 - Connection diagram
NOTE:
The digital control unit
ERESCO MF4 control can operate with restrictions
(see section 3.), also as stand-alone equipment (without X-ray unit).
X1
X1
X5
Radiating unit
Control unit
Connecting cable
Power supply cable
230 V / 115 V
min. 10 mm² Cu
additional ground