4
To Start
K0394 Issue 3 - [EN] English
Key to figure A2
(Display)
Table 2: Key to figure A2
Key to figure A3
(Accessories)
Table 3: (Part of Table) Key to figure A3
Item
Description
11.
5-digit main display.
12.
2.5-digit percentage indicator (0-100% FSO).
%FSO = [applied pressure/(FSOHigh—FSOLow)] * 100
13.
20 segment analog dial in increments of 5% FSO (large division
marks = 10% increments).
%FSO = [applied pressure/(FSOHigh—FSOLow)] * 100
14.
The units of measurement: kPa, MPa, kg/cm
2
, psi, mbar, bar,
mmHg, mmH
2
O, mH
2
O, inH
2
O, inHg.
15.
Mode indication.
Voltage output (Vout) mode - On.
RS232 connection.
The data transmit/receive function is active.
Switch mode - On.
To monitor an external pressure switch.
= switch closed
= switch open
Menu Lock mode - On.
To restrict access to the menu functions.
Alarm mode - On.
The symbol flashes when the measured value
satisfies one of the alarm conditions.
= High alarm
= Low alarm
Maximum/minimum mode - On.
IDOS
UPM
mode - On.
To monitor pressure from a UPM
16.
Low battery power indication: Battery life
≤
15%.
Option Description
(A)
Part No. IA4090-1-V0: DPI 104 to PC RS232 cable (8-pin to 9-pin
D-type connector). To transmit data to a PC for applicable
monitor and control software (accessory D).
(B)
Part No. IA4101-1-V0: DPI 104 to UPM cable assembly. The
assembly has these connections:
UPM cable + 5-pin connector:
To give an IDOS UPM a 3 V power
supply and an RS232 connection to the DPI 104 - Figure B2 (d).
GND:
Ground connection.
V-OUT:
To supply a voltage output (Vo) - Figure B2 (c).
ALARM:
To supply an alarm output - Figure B2 (b).
SWITCH:
To monitor an external switch - Figure B2 (a).
12V:
12V input for accessory C - Figure B2.
Note: The assembly can supply 12 V to the DPI 104
and
3 V to the
IDOS
UPM
.
(C)
Part No. 191-129: Universal 12V power supply for accessory B.
(D)
Part No. 1S-SICALPRO-DPI104: SiCal
PRO monitor and control
software. This includes accessory A.