5.5.4 Split
reporting
Split reporting configures the control panel to report to two different central stations.
Some events must be reported to phone number 1 and others to phone number 2. The
control panel dials the first number twice. If it cannot reach this number, it dials the
second number twice. It performs this sequence for the number of times specified in
ARC
Dial Attempts
or until it reports the relevant event to each number. The same account
code is used to report to both numbers. Events for phone number 1 are enabled by
default and events for phone numbers 2 are disabled by default.
Level 1
Level 2
Value
State
Phone Number
Phone Number 1
123456
Phone Number 2
456789
Account Code
Phone Number 1
445566
Phone Number 2
445566
Protocol
Phone Number 1
SIA
Phone Number 2
SIA
Events
Phone Number 1 – Alarms
Enabled
Phone Number 1 – Alarm Restores
Enabled
Phone Number 1 – Tampers
Disabled
Phone Number 2 – Alarms
Disabled
Phone Number 2 – Alarm Restores
Disabled
Phone Number 2 – Tampers and Restores
Enabled
Summary of Contents for CS5500
Page 1: ...CS875 575 275 175 Alarm system CS5500 Programming Manual September 2003 ...
Page 83: ......
Page 84: ...1045335 ...